13

14.0

REMOVAL OF PUMP HEAD AND REPLACEMENT OF DIAPHRAGM (Continued)









FIGURE IX

FIGURE X


15.0

REMOVAL OF MOTOR FROM STANDARD “dia-PUMP” (REFER TO FIGURE XI)

15.0.1 Disconnect all wires leading to the motor.

15.0.2 Remove Drain Plug (FIG. #510) and drain hydraulic fluid from pump.

15.0.3 Remove the fan cover and fan if the motor is a TEFC type. Remove retaining bolts from the top of the motor.

These bolts are threaded directly into the Pump Gear Box (FIG. #500).

15.0.4 Turn case of motor gently to break silicone seal between motor casing and Pump Gear Box (FIG. #500). Tilt

motor slightly forward and remove housing and remove internal part.

15.0.5 To replace motor, clean machined surface at top of Gear Box (FIG. #500) and apply silicone sealer. Place

motor back in position generally reversing the disassembly procedure.




















FIGURE XI