IIXX.. TTrroouubblleesshhoooottiinngg G

Guuiiddee

(cont.)

PPRRO

OBBLLEEM

M

PPoossssiibbllee CCaauussee

CCoorrrreeccttiivvee AAccttiioonn

IInnddiiccaattiioonn:: m

meecchhaanniiccaall ffaauulltt

(

(ccoonntt..))

• Packing box(es) too tight, too loose, wrong

Adjust, relubricate or replace packing; align box(es).

packing, packing dried or worn out, out of

alignment.

• Mechanical seals misaligned, broken or

Realign or replace seals or parts.

worn out.

• Solids or liquids passing through machine.

Disassemble, inspect and clean machine; install inlet

filter to prevent further contamination.

• Soft foot on motor or blower.

See page 5.

• Machine in surge (see page 8).

Increase airflow.

• Stacked impeller hub nuts too tight.

Loosen hub nuts 1/2 turn.

• Belts on belt drive machine loose, slapping.

Tighten belts to proper tension.

• Harmonic pulsation from gasoline

Change engine speed to remove pulsation.

engine driver.

• Machine not on solid foundation.

Reinforce foundation.

M

MO

OTTO

ORR HHO

OTT

((CChheecckk wwiitthh ssuurrffaaccee tthheerrm

moom

meetteerr;; ccoonnssuulltt SSppeenncceerr SSeerrvviiccee DDeeppaarrttm

meenntt ffoorr aassssiissttaannccee))

• Ambient temperature too high for insu-

Cool motor or replace with motor having proper insulation.

lation class.

• Incorrect voltage.

Change to correct voltage.

• Incorrect cycle.

Change to correct cycle.

• Electrical short-circuit insulation failure.

Repair or replace motor.

• Motor overloaded, too much air

Check for system leaks, throttle back butterfly valve,

passing through blower.

install larger motor.

• Unbalanced voltage supply (gas boosters

Check power company for correction.

only).

M