Spencer 4BOB Multistage Centrifugal Blowers User Manual
Page 18
1188
IIXX.. TTrroouubblleesshhoooottiinngg G
Guuiiddee
(cont.)
PPRRO
OBBLLEEM
M
PPoossssiibbllee CCaauussee
CCoorrrreeccttiivvee AAccttiioonn
IInnddiiccaattiioonn:: m
meecchhaanniiccaall ffaauulltt
(
(ccoonntt..))
• Packing box(es) too tight, too loose, wrong
Adjust, relubricate or replace packing; align box(es).
packing, packing dried or worn out, out of
alignment.
• Mechanical seals misaligned, broken or
Realign or replace seals or parts.
worn out.
• Solids or liquids passing through machine.
Disassemble, inspect and clean machine; install inlet
filter to prevent further contamination.
• Soft foot on motor or blower.
See page 5.
• Machine in surge (see page 8).
Increase airflow.
• Stacked impeller hub nuts too tight.
Loosen hub nuts 1/2 turn.
• Belts on belt drive machine loose, slapping.
Tighten belts to proper tension.
• Harmonic pulsation from gasoline
Change engine speed to remove pulsation.
engine driver.
• Machine not on solid foundation.
Reinforce foundation.
M
MO
OTTO
ORR HHO
OTT
((CChheecckk wwiitthh ssuurrffaaccee tthheerrm
moom
meetteerr;; ccoonnssuulltt SSppeenncceerr SSeerrvviiccee DDeeppaarrttm
meenntt ffoorr aassssiissttaannccee))
• Ambient temperature too high for insu-
Cool motor or replace with motor having proper insulation.
lation class.
• Incorrect voltage.
Change to correct voltage.
• Incorrect cycle.
Change to correct cycle.
• Electrical short-circuit insulation failure.
Repair or replace motor.
• Motor overloaded, too much air
Check for system leaks, throttle back butterfly valve,
passing through blower.
install larger motor.
• Unbalanced voltage supply (gas boosters
Check power company for correction.
only).
M
MAACCHHIINNEE
VVIIBBRRAATTIINNG
G