Spencer 4BOB Multistage Centrifugal Blowers User Manual
Page 17
1177
IIXX.. TTrroouubblleesshhoooottiinngg G
Guuiiddee
(cont.)
PPRRO
OBBLLEEM
M
PPoossssiibbllee CCaauussee
CCoorrrreeccttiivvee AAccttiioonn
IInnddiiccaattiioonn:: m
maacchhiinnee m
maallffuunnccttiioonn –– iinntteerrnnaall nnooiissee
• Impellers and/or deflectors worn due to age
Correct abrasive conditions if present; replace impellers
or abrasion from dirty air or gas.and/or deflectors.
• Impeller(s) hitting after customer reassembly
Reassemble according to instructions, tighten impellers.
and/or impeller(s) slipping shaft due to heat
Bleed air at low flow to reduce heat. Change inlet
or excessive inlet pressure.
conditions if necessary.
• Machine in surge (see page 8).
Increase airflow.
• Keyed hubs rattling on startup.
Normal condition (loose when cold, tight at operating
temperature).
• Machine running rough, out of balance.
Rebalance and/or clean machine (see next topic
Machine Vibrating).
• Deflector packings rubbing on shaft or
Ignore if audible only when machine is turned by hand. If
impeller hub (will seat themselves if new).
otherwise audible, replace packings.
• Motor not aligned in housing (SOH)
Reassemble and carefully align shaft and motor.
causing impeller to hit.
• Coupling misaligned and/or out of grease
Check alignment; check coupling for wear and replace if
(4BOH & 4BOB).
necessary; relubricate according to instructions.
• Foreign material in machine.
Disassemble machine, inspect and clean. Reassemble
and consider installing filter to prevent clogging.
IInnddiiccaattiioonn:: m
moottoorr m
maallffuunnccttiioonn
• Abnormal hum or whine.
Check motor manufacturerʼs instructions; check voltage
supply and connections.
• Low voltage, motor not up to speed.
Correct improper voltage.
• High voltage (causes noise and burnout).
Correct improper voltage.
• Bearing noise.
See previous instructions for blower bearings.
• Loose part in motor.
Tighten, repair or replace (check motor manufacturer).
• Low frequency.
Correct improper frequency.
IInnddiiccaattiioonn:: m
meecchhaanniiccaall ffaauulltt
• Material buildup on impellers.
Clean impellers, install inlet filter to prevent further buildup.
• Shaft bent.
Consult Spencer Service Department.
• Bearing failure.
Replace bearing(s).
• Unbalanced replacement motor installed.
Balance motor.
• Impeller failure.
Replace impeller(s).
• Motor not aligned in housing (SOH & 4BOH),
Align motor, realign shaft.
impeller rubbing.
• Coupling misaligned (4BOH & 4BOB).
Align coupling.
• Inlet and/or discharge piping connected
Install flexible connectors at inlet and discharge.
to machine without flexible connector,
causing torque or stress on housing.
• Machine bolted down, causing
Remove bolts, use dowel pins or set in guide channels.
misalignment.
• Bearing(s) cramped due to improper fit.
Check bearings, shaft and housing, correct bearing fit.
• Piping not adequately supported.
Anchor piping properly beyond flexible connector.
• Incorrect motor voltage, causing assembly
Check voltage and wiring connections, correct voltage.
to operate at improper speed.
M
MAACCHHIINNEE
NNO
OIISSYY
M
MAACCHHIINNEE
VVIIBBRRAATTIINNG
G