Spencer 4BOB Multistage Centrifugal Blowers User Manual
Page 16
1166
PPRRO
OBBLLEEM
M
PPoossssiibbllee CCaauussee
CCoorrrreeccttiivvee AAccttiioonn
IInnddiiccaattiioonn:: llooww pprreessssuurree//vvaaccuuuum
m aass ddeetteerrm
miinneedd bbyy ggaauuggee m
meeaassuurreem
meenntt oorr pprroocceessss
• Incorrect rotation.
Change motor leads to correct rotation.
• Air or gas lines too small, causing
Increase line sizes or install machine with higher output
excessive friction loss.
pressure.
• Machine reassembled incorrectly in field.
Disassemble machine and reassemble correctly.
• Valves in line not fully open or check
Open valves or inspect check valve.
valve improperly installed.
• Inlet, discharge or piping system
Remove obstructions, clean filter.
partially blocked.
• High inlet temperature.
Position inlet in a cooler area.
• Low inlet pressure.
Check inlet for obstructions or install machine with higher
discharge pressure.
• Machine not running at design speed.
Refer to motor manufacturerʼs instructions; check motor
speed; check voltage connections.
• Low gas density or specific gravity.
Check gas analysis and increase density or install
machine designed for prevailing conditions.
• Machine air passages clogged.
Disassemble, clean and inspect all parts.
• Impellers damaged by explosion,
Replace impellers.
abrasion or vibration.
• Inlet spiral has rotated, partially blocking
Rotate spiral to correct position and pin or clamp in
inlet (4BOB only).
position.
• Pressure or vacuum gauge inaccurate.
Calibrate gauge; always use a “U” tube manometer for
checking pressure and/or vacuum.
IInnddiiccaattiioonn:: m
maacchhiinnee ddeessiiggnn ccaappaacciittyy ttoooo ssm
maallll ffoorr tthhee ssyysstteem
m
• System requirements incorrectly calculated
Install larger volume or lower pressure machine to handle
by customer.
system requirements.
• System leaks or too many openings.
Locate and repair leaks; reduce number of openings.
IInnddiiccaattiioonn:: m
meeaassuurriinngg ggaass oorr aaiirrffllooww iinnccoorrrreeccttllyy
• Flowmeters calibrated incorrectly.
Calibrate flowmeters; use proper orifice for meter (check
with flowmeter manufacturer).
• No means of measurement available.
Obtain and install flowmeter.
IInnddiiccaattiioonn:: m
maacchhiinnee m
maallffuunnccttiioonn –– bbeeaarriinngg wwhhiinniinngg oorr ggrroowwlliinngg
• Too much grease, bearings hot.
Remove excess grease. Check bearing temperature;
refer to lubrication instructions in this manual.
• Too little grease, bearings dry.
Grease according to instructions.
• Bearing failure.
Replace bearing(s).
• Bearing retainers worn.
Replace bearing(s).
• Bearing turning on shaft, retaining nut loose.
Tighten nut, check for damage.
• Bearing turning in housing, housing worn.
Replace housing and bearing.
• Bearing replaced incorrectly, particularly in
Follow installation instructions carefully; check bearing,
tandem assembly (e.g., angled, cramped
shaft and housing dimensions.
or reversed).
• Bearing(s) overloaded—too much thrust
Replace bearing(s); reduce thrust by lowering air or gas
due to high density air or gas.
density; install smaller impellers or install machine
designed for application conditions.
IIXX.. TTrroouubblleesshhoooottiinngg G
Guuiiddee
IINNSSUUFFFFIICCIIEENNTT
AAIIRR O
ORR G
GAASS
TTHHRRO
OUUG
GHH
SSYYSSTTEEM
M
M
MAACCHHIINNEE
NNO
OIISSYY