1166

PPRRO

OBBLLEEM

M

PPoossssiibbllee CCaauussee

CCoorrrreeccttiivvee AAccttiioonn

IInnddiiccaattiioonn:: llooww pprreessssuurree//vvaaccuuuum

m aass ddeetteerrm

miinneedd bbyy ggaauuggee m

meeaassuurreem

meenntt oorr pprroocceessss

• Incorrect rotation.

Change motor leads to correct rotation.

• Air or gas lines too small, causing

Increase line sizes or install machine with higher output

excessive friction loss.

pressure.

• Machine reassembled incorrectly in field.

Disassemble machine and reassemble correctly.

• Valves in line not fully open or check

Open valves or inspect check valve.

valve improperly installed.

• Inlet, discharge or piping system

Remove obstructions, clean filter.

partially blocked.

• High inlet temperature.

Position inlet in a cooler area.

• Low inlet pressure.

Check inlet for obstructions or install machine with higher

discharge pressure.

• Machine not running at design speed.

Refer to motor manufacturerʼs instructions; check motor

speed; check voltage connections.

• Low gas density or specific gravity.

Check gas analysis and increase density or install

machine designed for prevailing conditions.

• Machine air passages clogged.

Disassemble, clean and inspect all parts.

• Impellers damaged by explosion,

Replace impellers.

abrasion or vibration.

• Inlet spiral has rotated, partially blocking

Rotate spiral to correct position and pin or clamp in

inlet (4BOB only).

position.

• Pressure or vacuum gauge inaccurate.

Calibrate gauge; always use a “U” tube manometer for

checking pressure and/or vacuum.

IInnddiiccaattiioonn:: m

maacchhiinnee ddeessiiggnn ccaappaacciittyy ttoooo ssm

maallll ffoorr tthhee ssyysstteem

m

• System requirements incorrectly calculated

Install larger volume or lower pressure machine to handle

by customer.

system requirements.

• System leaks or too many openings.

Locate and repair leaks; reduce number of openings.

IInnddiiccaattiioonn:: m

meeaassuurriinngg ggaass oorr aaiirrffllooww iinnccoorrrreeccttllyy

• Flowmeters calibrated incorrectly.

Calibrate flowmeters; use proper orifice for meter (check

with flowmeter manufacturer).

• No means of measurement available.

Obtain and install flowmeter.

IInnddiiccaattiioonn:: m

maacchhiinnee m

maallffuunnccttiioonn –– bbeeaarriinngg wwhhiinniinngg oorr ggrroowwlliinngg

• Too much grease, bearings hot.

Remove excess grease. Check bearing temperature;

refer to lubrication instructions in this manual.

• Too little grease, bearings dry.

Grease according to instructions.

• Bearing failure.

Replace bearing(s).

• Bearing retainers worn.

Replace bearing(s).

• Bearing turning on shaft, retaining nut loose.

Tighten nut, check for damage.

• Bearing turning in housing, housing worn.

Replace housing and bearing.

• Bearing replaced incorrectly, particularly in

Follow installation instructions carefully; check bearing,

tandem assembly (e.g., angled, cramped

shaft and housing dimensions.

or reversed).

• Bearing(s) overloaded—too much thrust

Replace bearing(s); reduce thrust by lowering air or gas

due to high density air or gas.

density; install smaller impellers or install machine

designed for application conditions.

IIXX.. TTrroouubblleesshhoooottiinngg G

Guuiiddee

IINNSSUUFFFFIICCIIEENNTT

AAIIRR O

ORR G

GAASS

TTHHRRO

OUUG

GHH

SSYYSSTTEEM

M

M

MAACCHHIINNEE

NNO

OIISSYY