beautypg.com

Extron Electronics VersaTools MTP Series Setup Guide User Manual

Page 15

background image

Refer also to the VersaTools

®

MTP Series User’s Manual at www.extron.com.

C

The length of exposed wires is critical. Ideal length is

3/16” (5 mm). If the stripped section of wire is longer than

3/16” the exposed wires may touch, causing a short circuit.

If the stripped section of wire is shorter, wires can easily be

pulled out even if tightly fastened by the captive screws.

N

Do not tin the stripped leads! Tinned wires are not as

secure in the captive screw and direct insertion connectors

and could be pulled out.

Verify the polarity before connection! Plug in the power supply

in with no load and check the output with a voltmeter.

W

The two power cord wires must be kept separate while the

power supply is plugged in. Remove power before wiring.

Use the supplied tie‑wrap to strap the power cord to the

extended tail of the connector.

N

The transmitter/receiver pair may have shipped with a blue

captive screw connector. This connector does not include

the extended tail or tie-wrap but can be plugged into either

a blue or an orange power receptacle.

Transmitter/receiver combinations containing new generation,

non‑jumpered (mono audio) units cannot be powered from a

single supply. The following table shows the combination of

old and new generation MTP units (jumper configured to the

stereo audio position) capable of remote powering (See "Signal

Jumpers for Generational Compatibity" on page 1‑3).

Single Power Supply (remote powering)
Transmitter

Receiver

Old Generation

Old Generation

Old Generation

New Generation, Jumpered*

New Generation, Jumpered*

Old Generation

New Generation, Jumpered*

New Generation, Jumpered*

*Configured for stereo audio

N

When configured for stereo audio, a single power supply

connected to either the transmitter or receiver can power

both units if there is less than 500 feet (150 meters) of

STP/UTP/FTP cable between the two. If the transmitter

and receiver are separated by greater than 500 feet, connect

a power supply to both units regardless of the model and

jumper configuration.

g

Power LED — Indicates power is applied to the MTP.

VersaTools

®

MTP Series • Installation

1-9