Twisted Pair Cable Termination
Figure 10 details the recommended termination of TP cables with RJ-45 connectors in
accordance with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You can use either
standard with CAT 5, 5e, 6, 7, and STP201 cable, but ensure that you use the same
standard on both ends of the cable.
RJ-45
Connector
Insert Twisted
Pair Wires
12345678
Pins:
Pin
Signal
1
Red/V. sync +
2
Red/V. sync -
3
Green +
4
Blue/H. sync +
5
Blue/H. sync -
6
Green -
7
Mono audio +
8
Mono audio -
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
TIA/EIA T 568 A TIA/EIA T 568 B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
NOTE: When using Enhanced Skew-Free
A/V UTP cable, use the
TIA/EIA T568A standard only.
Figure 10.
TP Cable Termination Diagram
NOTES:
•
RJ-45 termination with CAT 5, 5e, or 6 cable (for non-C7 units only) or
STP201 or CAT 7 cable (for C7 units only) must comply with the
TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.
•
RJ-45 termination with Skew-Free A/V UTP cable (for non-C7 units only)
must comply with TIA/EIA T568A only.
•
For proper grounding of STP201 and CAT 7 cable only, ensure the shield
around each wire pair and the shield around the STP201 or CAT 7 cable
are all tied to the RJ-45 connectors on both ends, in accordance with the
connector specifications provided by the manufacturer.
•
Extron Enhanced Skew-Free A/V cable is not recommended for Ethernet/
LAN applications. This cable is specially designed for compatibility with Extron
Twisted Pair products that are wired using the TIA/EIA T568A standard.
•
The green, brown, and blue wire pairs of this cable have virtually identical
lengths and should be used to transmit the RGB signals.
•
The orange wire pair of this cable has a different length and should not be
used to transmit the RGB signals.
MTP 15HD RS Series • Installation and Operation