Extron • Matrix 3200/6400 Series • User’s Manual

Chapter 5 • Upgrades and Troubleshooting

AC POWER INPUT

FUSE: 250V 0.8A TT

100-240V 0.5A MAX 50/60Hz

Checking/Replacing the BME External AC Input Fuse

The AC power input cord plugs into the Power-Switch/Fuse assembly which is
located on the rear panel in the lower left corner of the BME. To check/replace
the external fuse, remove the power-cord and insert the tip of a small
screwdriver blade into the fuse-holder slot (the fuse-holder is located
just below the power-switch). Pry the fuse-holder out, it contains the
AC input fuse plus a spare. If may be obvious that the fuse is blown,
if not, check it with an ohmmeter or any other continuity device if
available. If the fuse is blown, replace it with the provided spare. Plug
the AC power cord in and Power the BME ON. Verify that the unit
powered ON correctly (check Front Panel LEDs). If the LEDs are in
the proper state, the problem has been corrected. If not, contact
Extron Technical Support.

Checking/Replacing the BME Internal Power Supply AC Input Fuses

Each internal power supply has an AC input fuse. If a power supply fuse blows,
the Front Panel LED for that power supply will go OFF (it is normally solid ON). If
the BME has redundant power supplies, the redundant supply for the failed
power supply will assume the full load and its front panel diagnostic LED will
blink indicating that the Main (Primary) power supply is inoperative. To check/
replace a power supply fuse, unplug the AC power cord from the BME rear
panel, remove the Access Panel (Front Panel if Sync BME - see Page 5-2).
Power supply fuse locations are shown in Figure 5-6.A (circled). Remove the
fuse from the problem power supply. If may be obvious that the fuse is blown, if
not, check it with an ohmmeter or any other continuity device if available. If the
fuse is blown, replace it, plug the AC power cord in, power up the BME and
check Diagnostic LEDs. If the problem persists, call Extron Technical Support.

5-6

POWER SUPPLIES

COMMUNICATIONS

PRIMARY

TX

RS232

BME

MKP

SYSTEM

STATUS

REDUNDANT

RX

DIAGNOSTICS

+V

-V

Redundant V+
Power Supply

Primary V+
Power Supply

1

2

19

J1

20

HIGH V

OLTAGE

CAUTION

Fuse

Cable

Fuse

HIGH VOLTAGE

CA

U

T

IO
N

PO

WER SUPPLIES

COMMUNICA

TIONS

PRIMAR

Y

TX

RS232

BME

REMO

TE

SYSTEM

ST

ATUS

REDUND

ANT

RX

DIA

GNOSTICS

+V

-V

Fuse

Primary V-
Power Supply
(Redundant V-
located above)

Figure 5-6.A

BME exploded view.

This manual is related to the following products: