Extron • Matrix 3200/6400 Series • User’s Manual

Chapter 5 • Upgrades and Troubleshooting

BME Internal Access

Upgrades or repairs may require access to internal areas of a BME. Internal
access for the 5U/7U high Sync BME requires removal of ten screws (see Figure
5-2.A) plus a ribbon cable allowing the front panel to be removed (if the Sync
BME is rack mounted and the case has no underneath support, it must be
removed from the rack before removing the front panel).

All other BMEs include an access panel (blank or FPC 1000) that can be
removed using a coin or a flat blade screwdriver to rotate the two captive screws
as shown in Figure 5-2.C and 5-2.D. Pull the top of the access panel out slightly
then lift up and remove it from the front panel. The FPC 1000 will have a cable
connecting it to the Main Controller, unplug the connector.

When done, reverse the procedure to reinstall the front panel or the access
panel.

Figure 5-2.B

Figure 5-2.D

RGB

MUTE

AUDIO

MUTE

Figure 5-2.C

MATRIX 6400

SYNC

POWER SUPPLIES

COMMUNICATIONS

PRIMARY

TX

RS232

BME

SYSTEM
STATUS

REDUNDANT

RX

DIAGNOSTICS

+V

-V

MATRIX 6400

WIDEBAND

POWER SUPPLIES

COMMUNICATIONS

PRIMARY

RGB

MUTE

AUDIO
MUTE

TX

RS232

BME

MKP

SYSTEM
STATUS

REDUNDANT

RX

DIAGNOSTICS

+V

-V

FPC-1000

Captive screws

Figure 5-2.A

For Sync BME, remove 10 screws.

A Ribbon Cable is located
behind panel in this area

5-2