Virtual Output MUTES

VM

1

2

• • • • •

64

Mut

Notes:
1. Start output is always Ø1 for Room PRESET, because room has max. of 16 outputs assigned.
2. All “VI” values in responses are 2 numeric characters (i.e. 12 or Ø3) or “na” indicating non-existant
virtual outputs
3. In “VA” View, any outputs that do not follow show as “- -“ in response
4. SO = “Start-Output” parameter in “Global Preset commands”.
5. Rvo - Rvo.... = Set of Virtual Outputs assigned to specified “room” (up to 16 total).

RGB D

ELAY

C

OMMANDS

ASCII (H

OST

-S

WITCHER

)

RESPONSE (S

WITCHER

-H

OST

)

Read RGB Delay (for 1 ch.)

D

Out

•Dly

Set RGB Delay (for 1 ch.)

d

*

Out

•Dly

Note: Where

= delay in 1/2 second increments (i.e. Ш = Ш sec, 1Ш = 5.Ш sec)

D

IRECT

W

RITE

OF

G

LOBAL

P

RESETS

C

OMMANDS

ASCII (H

OST

-S

WITCHER

)

RESPONSE (S

WITCHER

-H

OST

)

Start Write Mode

P

Write Preset

Ready

End Write Mode

p

End Write Preset

Example

P32

Write Preset 32 Ready

1*1!
1*2&
1*3%
:
:
1*64$

p

End Write Preset 32

Notes:
1. Any non-output switching or invalid command between the Start and End commands will be ignored.
2. If there is no activity for 5 seconds while in write mode, then error E17 occurs.
3. No front panel switching (Actual Switching) is allowed during the Start and End commands.
4. If an End command

p command is issued with no Start command, then error E10 occurs.

Q

UICK

R

ECALL

OF

G

LOBAL

P

RESETS

C

OMMANDS

ASCII (H

OST

-S

WITCHER

)

RESPONSE (S

WITCHER

-H

OST

)

Quick Recall Preset

.

Rpr

Notes:
1. If the Quick Recall Preset (

.) command is issued without an active write, then error E10 occurs.

2. Complete backplane switch within 60mSeconds (apprx.) after receipt of the command.
3. Recall must take place 100mSeconds after End Write Mode command (

p

).

4. Quick recall command only recalls last entered direct write preset.

S

ET

N

AMES

C

OMMANDS

ASCII (H

OST

-S

WITCHER

)

RESPONSE (S

WITCHER

-H

OST

)

Read Global preset name

NG

Write Global preset name

nG

,

NamG

Read Room preset name

NP

*

Write Room preset name

nP

*

,

NamP

Read Room Name

NR

Write Room Name

nR

,

NamR

Read Virtual Input Name

NI

Write Virtual Input Name

nI

,

NamI

Read Virtual Output Name

NO

Write Virtual Output Name

nO

,

NamO

A

DVANCED

I

NSTRUCTION

S

ET

AND

S

IMPLE

I

NSTRUCTION

S

ET

C

OMMANDS

(P

AGE

3

OF

3)

This manual is related to the following products: