1-9

Impedance ................................. 75 ohms

Return loss ................................. -25 dB to input section up to 50 MHz

DC offset .................................... ±10 mV typical with input at 0 offset

Switching type ............................ Triple-Action

Slew rate .................................... >200 V/ms

Sync — sync BME

Input and output types ................ Software configurable for RGBHV or RGBS

Sync connectors ......................... Up to 64 or 32 BNC female (quantity varies with configuration)

Input level ................................... 0.5 V to 5 Vp-p (4 Vp-p nominal)

Output level ................................ 5 Vp-p

Gain ........................................... AGC to TTL : 4.0 V to 5.0 Vp-p

Input impedance ......................... Inputs 1 - 16: 510 ohms or 75 ohms, switchable

Inputs 17 - 64: 510 ohms

Output impedance ...................... 75 ohms

Horizontal frequency .................. 15 kHz to 150 kHz

Vertical frequency ...................... 30 Hz to 150 Hz

Polarity ....................................... Positive or negative (follows input)

Control/remote — switcher

Serial control port ....................... RS-232 or RS-422, 9-pin female D connector

Baud rate and protocol ............... 9600 baud, 8 data bits, 1 stop bit, no parity

Serial control pin configurations ..... 2 = TX, 3 = RX, 5 = GND

System intercommunications ...... 2 RJ-11 connectors

Remote keypad control .............. (2) 5 mm, 5-pole captive screw connectors

Program control .......................... Extron’s control/configuration program for Windows

®

Extron’s Simple Instruction Set (SIS

)

General

Power* ....................................... 100 VAC to 240 VAC, 50/60 Hz; internal, autoswitchable

Matrix 6400 wideband110 watts at 115 VAC, 60 Hz
Matrix 3200 wideband50 watts at 115 VAC, 60 Hz
*A redundant power supply is available.

Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling ....................................... Fan, left to right, as facing the front panel

Rack mount ................................ Yes

Enclosure type ........................... Metal

5U dimensions ........................... 8.75" H x 17.0" W x 14.1" D (5U high, full rack wide)

22.2 cm H x 43.2 cm W x 35.8 cm D
(Depth excludes connectors. Width excludes rack ears.)

7U dimensions ........................... 12.25" H x 17.0" W x 14.1" D (7U high, full rack wide)

31.1 cm H x 43.2 cm W x 35.8 cm D
(Depth excludes connectors. Width excludes rack ears.)

Shipping/product weight, rack height

Matrix 6400 wideband . 42 lbs (20 kg)/29.1 lbs (13.2 kg), 7U
Matrix 3200 wideband . 30 lbs (14 kg)/22.2 lbs (10.1 kg), 5U
DIM weight, international (all models)
44 lbs (20 kg)

Vibration ..................................... ISTA 1A in carton (International Safe Transit Association)

Listings ....................................... UL, CUL

Compliances .............................. CE, FCC Class A

MTBF ......................................... 30,000 hours

Warranty .................................... 3 years parts and labor

All nominal levels are at ±10%.

Specifications are subject to change without notice.