Serial communication, cont’d – Extron Electronics IN1502 User Guide User Manual
Page 34

Serial Communication, cont’d
IN1502 • Serial Communication
3-6
Freeze
Enable
1F
Frz1
Output a “frozen” video
image.
Disable
0F
Frz0
Turn off freeze (output
motion).
View the freeze status
f/F
Frz
X2
Show the freeze status.
Example:
F
Frz 0
Example: Freeze is disabled.
Front panel security lockout (Executive mode)
Enable (lock image adjustments)
1X
Exe1
Lock front panel adjustments;
adjust image via RS-232 only.
Disable
0X
Exe0
Adjustments and selections
are made from the front panel.
View the executive mode status
X
Exe
X2
Show executive mode status.
Example:
X
Exe 1
Example: The front panel is
locked.
Software version and build number requests
Query software version number
Q/q
x.xx
Show the software version.
Show version and build number
*Q
x.xxx.xxx
Show the version and build
number.
Part number request
Show the DVS 202’s part number
N/n
60-726-01
Show the scaler’s part number.
Information request
Show the current input number
I/i
Chn
X1
•Std
X6
Show the scaler’s input
number and signal standard.
Zap (reset to default settings)
Total reset
Esc
zXXX
ZapXXX
Reset everything: all settings
and adjustments to the factory
default.
Image adjustment reset
Esc
zI
ZapI
Reset image adjustments to
factory settings.
Command/response table for SIS commands (continued)
Command
ASCII Command Response
Additional description
(host to scaler)
(scaler to host)