Wiring the system 7sc’s captive screw connector, Wiring the mlc’s one-piece captive screw connector – Extron Electronics IR Broadcaster User Manual
Page 7
7
IR Broadcaster with Emitter Port • Installation and Operation
7
1/4” (0.6 cm) of insulation from each wire. Do not solder the tips. Insert
each wire into the correct position on the captive screw connector, and
tighten each screw. See the diagrams below.
To pass through an IR signal that includes a carrier signal,
connect the signal wire to the pin designated for carrier and
signal.
If you want the IR Broadcaster to generate the carrier signal,
connect the signal wire to the pin designated for signal only.
System 5
Comm port
Signal only
Gnd
Carrier & signal
Gnd
+12V
COMM
Tip (+12V)
Sleeve (Gnd)
Tip (+12V)
Ring (Signal)
Sleeve (Gnd)
To the
IR Broadcaster
(60-272-02)
A
B
C
D
E
Wiring the System 5/5cr/5cr Plus’ captive screw connector
Carrier & signal
Signal only
Gnd
+12V
System 7
IR Comm
port
IR COMM
A
B
C
D
E
To IR Broadcaster
with emitter port
(#60-272-02)
E
D
C
A
Wiring the System 7SC’s captive screw connector
Demodulated IR (signal only)
+12VDC output
MLC IR
Display/Source
Control port
A B C D E
IR
Modulated IR (signal & carrier)
Ground
To
IR Broadcaster
with Emitter port
(#60-272-02)
E
D
C
A
Wiring the MLC’s one-piece captive screw connector