beautypg.com

Rear panel, A note on i/o boards, A note on i/o boards -2 – Extron Electronics FOX 4G Matrix 7200 Setup Guide User Manual

Page 8: Installation, Fox 4g matrix switchers • installation, Fiber optic connectors and leds — see page 2-4, Sdi/hdi-sdi bnc connectors — see page 2-5, Remote port — see page 2-5, Ethernet port (lan connector) — see page 2-5, Switch reference connectors — see page 2-5

background image

2-2

Refer also to the FOX 4G Matrix Switchers User’s Manual at www.extron.com.

Refer also to the FOX 4G Matrix Switchers User’s Manual at www.extron.com.

Rear Panel

A note on I/O boards

See figure 2-1. Each I/O board is identified by the input and

output numbers supported by the board position. The transceiver

modules on the I/O boards are identified as A through H.

ANAHEIM, CA

100-240V 50/60Hz 1.2A MAX.

PRIMARY POWER SUPPLY

1 - 8

9 - 16

17 - 24

A

B

C

D

E

F

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

A

B

C

D

E

F

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

25 - 32

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

D

C

A

D

C

B

Location A

Input

Location A

Output and Input

Slot 1

(1-8)

O#1

I#1

Slot 2

(9-16)

Slot 3

No board

installed

Slot 4

(25-32)

O#2

I#2

O#3

I#3

O#4

I#4

O#9

I#25

I#26

I#27

I#28

I#29

I#30

I#31

I#32

O#25

O#26

I#9

O#10

I#10

O#11

I#11

O#12

I#12

O#5

I#5

O#6

O#13

I#13

O#14

Location A

Output

Location H

Input

1

1

2

Figure 2-1 — Arrangement of inputs and outputs on
the I/O boards

The board position designators correspond to the input and

output numbers served by that position (1 - 8, 9 - 16, and so on).
The location designators, A through H, correspond to the

transceiver modules, numbered from left to right, each of which

includes an input and an output.
See figure 2-1. The input and output numbers supported by the

I/O board in location 9 - 16 are as follows: A = 9, B = 10, C = 11,

D = 12, E = 13, F = 14, G = 15, and H = 16.)

a

Fiber optic connectors and LEDs — See page 2-4.

b

SDI/HDI-SDI BNC connectors — See page 2-5.

c

Remote port — See page 2-5.

d

Ethernet port (LAN connector) — See page 2-5.

e

Switch Reference connectors — See page 2-5.

f

Power connectors — See page 2-5.

g

Power indicator LEDs — See page 2-5.

h

Replaceable fan(s) — See chapter 5, "Maintenance and

Modifications", to replace the fan.

Figure 2-2 — FOX 4G Matrix 3200 Switcher rear panel

ANAHEIM, CA

RESET

SWITCH REFERENCE

BI-LEVEL

TRI-LEVEL

RS232/RS422

REMOTE

LAN

ACT LINK

REDUNDANT

PRIMARY

PRIMARY POWER SUPPLY

REDUNDANT POWER SUPPLY

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

FAN ASSIMBLY

FAN ASSIMBLY

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

100-240V

50/60Hz

1.2A MAX.

100-240V

50/60Hz

1.2A MAX.

DISCONNECT BOTH POWER
CORDS BEFORE SERVICING

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

65 - 72

1

4

6

5

7

3

7

2

8

1 - 8

9 - 16

17 - 24

25 - 32

33 - 40

41 - 48

49 - 56

57 - 64

65 - 72

Figure 2-3 — FOX 4G Matrix 7200 Switcher rear panel

ANAHEIM, CA

RESET

REMO

TE

RS-232/RS-422

LAN

BI-LEVEL

TRI-LEVEL

A

CT LINK

100-240V 50/60Hz 1.2A MAX.

100-240V 50/60Hz 1.2A MAX.

REDUND

ANT

PRIMAR

Y

DISCONNECT BO

TH PO

WER

CORDS BEFORE SER

VICING

SWITCH

REFERENCE

PRIMARY POWER SUPPLY

REDUNDANT POWER SUPPLY

1 - 8

9 - 16

17 - 24

A

B

C

D

E

F

G

H

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

C

D

E

F

G

H

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

A

B

C

D

E

F

G

H

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

25 - 32

MUTI-RATE SDI INPUTS

H

G

A

D

E

F

C

B

MUTI-RATE SDI OUTPUTS

H

G

A

D

E

F

C

B

1

3

4

6

5

7

7

2

8

1 - 8

9 - 16

17 - 24

25 - 32

BI-LEVEL

TRI-LEVEL

DISCONNECT BO

TH PO

WER

CORDS BEFORE SER

VICING

SWITCH

REFERENCE

FOX 4G Matrix Switchers • Installation

Installation

FOX 4G Matrix Switchers • Installation

2-3

This manual is related to the following products: