beautypg.com

Remote contr ol, cont’d – Extron Electronics FOX 4G Matrix 7200 Setup Guide User Manual

Page 14

background image

Refer also to the FOX 4G Matrix Switchers User’

s Manual at www

.extron.com.

Refer also to the FOX 4G Matrix Switchers User’

s Manual at www

.extron.com.

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Create ties

N

• Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003%.

The matrix switchers support 1-, 2-, and 3-digit numeric entries (1*1!, 02*02&, or 003*003%).

N

The ! tie command, the

& tie command, and the % tie command can be used interchangeably.

N

The ! read tie command,

& read tie command, and the % read tie command can be used interchangeably.

Tie input

X!

to output

X@

X!

*

X@

!

Out

X@

In

X!

All

]

Tie input

X!

to output

X@

.

Example (see Note, above):

1*3!

Out03•In01•All

]

Tie input 1 to output 3.

Tie input

X!

to output

X@

X!

*

X@

&

Out

X@

In

X!

RGB

]

Tie input

X!

to output

X@

.

Example (see Note, above):

10*4&

Out04•In10•RGB

]

Tie input 10 to output 4.

Tie input

X!

to output

X@

X!

*

X@

%

Out

X@

In

X!

Vid

]

Tie input

X!

to output

X@

.

Example (see Note, above):

7*5%

Out05•In07•Vid

]

Tie input 7 to output 5.

Read output tie

X@

&

X!]

Input

X!

is tied to output

X@

.

Read output tie

X@

%

X!]

Input

X!

is tied to output

X@

.

Read output tie

X@

!

X!]

Input

X!

is tied to output

X@

.

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional description

Channel mute commands

Channel mute

X@

*1B

Vmt

X@

*1

]

Mute output

X@

(no signal is output, but

the light output remains active).

Channel unmute

X@

*0B

Vmt

X@

*0

]

Unmute output

X@

(signal is output).

Read channel mute

X@

B

X#]

1 = mute on, 0 = mute off.

Global channel mute

1*B

Vmt1

]

Mute all light outputs.

Global channel unmute

0*B

Vmt0

]

Unmute all light outputs.

View output mutes

E

VM

}

X#

1

,

X#

2

, ...

X#

n

]

Each

X#

response is the mute status of an

output, starting from output 1.
n

= the maximum number of outputs for

your configuration.

Save and recall presets

N

If you try to recall a preset that is not saved, the matrix switcher responds with the error code

E11.

Save current configuration as a
global preset

X$,

Spr

X$]

Command character is a comma.

Example:

9

,

Spr09

]

Save current ties as preset 9.

Recall a global preset

X$.

Rpr

X$]

Command character is a period.

Example:

5

.

Rpr05

]

Recall preset 5, which becomes the current
configuration.

N

X!

= Input number

00 – (maximum number of inputs for your configuration) (00 = untied)

X@

= Output number

01 – (maximum number of outputs for your configuration)

N

X@

= Output number

01 – (maximum number of outputs for your model)

X#

= Mute

0 = not muted, 1 = muted

X$

= Global or room preset #

00 - 64