Serial Communication, cont’d
DVS 204 • Serial Communication
3-6
Freeze
Enable
1F
Frz1
Output a “frozen” video
image.
Disable
0F
Frz0
Turn off freeze (output
motion).
View the freeze status
F
Frz
X2
Show the freeze status.
Example:
F
Frz0
Front panel security lockout (Executive mode)
Disable
0X
Exe0
Adjustments & selections can
be made from the front panel.
Enable (lock image adjustments)
1X
Exe1
Lock front panel adjustments;
adjust image via RS-232 only.
View the executive mode status
X
Exe
X16
Show executive mode status.
Example:
X
Exe0
Firmware version, part number & information requests
Query firmware version number
Q
Ver
X8
Show the controller firmware
version.
Request part number
N
N60-442-0_
Show the scaler’s part #.
Request general info.
I
(See below)
Show the scaler’s status.
C
X1
•Typ
X4
•Std
X12
•Pre
X19
•Sdi
X1
Zap (reset to default settings)
Zap image adjustments/controls
Esc
zI
ZapI
Reset the image adjustments
to factory settings.
Zap all DVS 204 settings/memories
Esc
zXXX
ZapXXX
Reset everything: all settings
and adjustments to the factory
default.
Command/response table for SIS commands (continued)
Command
ASCII Command Response
Additional description
(host to scaler)
(scaler to host)