beautypg.com

Installation and operation, cont’d – Extron Electronics DVS 204 Series User Manual

Page 16

background image

Installation and Operation, cont’d

DVS 204 • Installation and Operation

2-6

S

R

/R-Y

V

G

/Y

H

B

/B-Y

OUTPUTS

RGBS from RGBS pass-through input

8

RGB or HD component (R-Y, Y, B-Y) 15-pin HD video output

— Connect

an RGB video display or HD component video display to this connector.

9

Remote (RS-232/contact closure) 9-pin port

— This connector provides for

two-way RS-232 communication and contact closure control. See chapter
three, “Serial Communication”, for information on how to install and use
the control software and SIS commands.

The default protocol is 9600 baud, 1 stop bit, no parity, and no flow control.

The rear panel RS-232 9-pin D female connector has the following pin
assignments:

Pin

RS-232 function

Description

1

Input #1

Contact closure

2

Tx

Transmit data

3

Rx

Receive data

4

Input #2

Contact closure

5

Gnd

Signal ground

6

Input #3

Contact closure

7

Input #4

Contact closure

8

No connection

9

Hardwired IR

IR input

The Remote connector also provides a way to select an input using a remote
contact closure device. Contact closure control uses pins on the Remote
connector that are not used by the RS-232 interface (see preceding table).

To select a different input number using a contact closure device,
momentarily short the pin for the desired input number to logic ground
(pin 5). To force one of the inputs to be always selected, leave the short to
logic ground in place. The short overrides front panel input selections.