When the image is displayed correctly

Once the system has been cabled and tested, the interface can

be installed in the wall or furniture. To mount the interface

and install optional MAAP devices (CIA111 only), see the next

section, "Mounting the Interfaces".

Au

to

Po

we

r

AU

DIO

IN

PU

T

MO

NIT

OR

OU

TP

UT

IMA

GE

SH

IFT

NO

MO

NIT

OR

CO

MP

UT

ER

IN

PU

T

Extron
CIA111

Computer Interface

Sound System

PC

Local Monitor

Presentation Monitor

Document
Camera

LAN/WAN

Network/

Internet

CIA11

1

Figure 2-5 — Typical CIA111 application

Mounting the Interfaces

This section describes how to mount the interfaces. Follow the

instructions that are appropriate to your interface.

C

Installation and service must be performed by

authorized personnel only.

Mounting the CIA111 or CIA114

The CIA111 mounts to a wall or podium using a two-gang

wall box. The CIA114 mounts in a one-gang wall box. The

installation must conform to national and local electrical codes

and to the equipment’s size requirements.

N

The CIA114 requires a minimum of 3.0” H x 2.0” W x

2.5” D space inside the wall box.

C

The CIA111 and CIA114 interfaces must be

installed into Underwriters Laboratories (UL)

approved electrical wall boxes. See the following

section on UL requirements. The wall boxes are

not included with the interfaces; the installer is

responsible for obtaining and installing the boxes.

UL Requirements

The following Underwriters Laboratories (UL) requirements

listed pertain to the installation of the CIA111 and CIA114

interfaces into a wall or furniture.
1

.

These units are not to be used beyond their rated voltage

range.

2

.

These units must be installed in UL listed junction boxes.

3

.

These units must be installed with conduit in accordance

with the National Electrical Code.

Preparing the site and installing the wall box

1

.

Choose an installation location that will allow cable runs

without interference. Allow enough depth for both the

wall box and the cables. You may need to install the cables

into the wall, furniture, or conduits before installing the

interface.

2

.

Use the appropriate template in appendix A, "Reference

Information", as a guide to measure and mark the hole in

the wall or furniture for installing the wall box.

C

The cut-out templates are not to scale and are

provided for reference only. Measure the hole

carefully before cutting.

3

.

Check the opening size by inserting the wall box into

the opening. The box should fit easily into the opening.

Enlarge or smooth the edges of the opening, if necessary.

4

.

Feed cables through the wall box punch-out holes, and

secure them with cable clamps to provide strain relief.

5

.

Exposed cable shields (braids or foil) are potential sources

of short circuits. Trim back and/or insulate shields with

heat shrink, if needed.

W

To prevent short circuits, the outer foil shield can

be cut back to the point where the cable exits the

cable clamp. Both braided and foil shields should be

connected to an equipment ground at the other end

of the cable.