beautypg.com

Wiring, Caution, Connecting quick connect cord – John Wood Noritz N-069M_N-069S User Manual

Page 60

background image

60

Connecting Quick Connect Cord

The wire coloring on the Quick Connect Cord will
not be the same as the wire coloring of the
connection plug inside the unit.
* The remote controller can be connected to either

unit A or B.

Caution

For Quick Connect Multi System Installation
usa a Quick Connect Cord (sold separately).

Quick Connect
Cord

"Quick Connect Cord" tag

A

B

1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue

1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue

1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue

1.White
2.Green
3.Red
4.Black
5.Blue
6.Blue

Connecting the Quick Connect Cord to the two
units.
1. Turn off the power.
2. Remove the front cover of the heater (4 screws).
3. Pass the Quick Connect Cord through the wiring

throughway and into the unit.

4. Plug the connector on the Quick Connect Cord to

the receptacle inside the unit.

5. Attach the ground wire of the Quick Connect

Cord to the terminal block fixing plate.
(If the ground wire is not attached, electrical nois
may cause problems).

6. Secure the Quick Connect Cord with a clamp.
7. Replace the front cover.

16A

16A

Wiring Throughway

Coupling Cord

Clamp

Ground wire
Connector

Connector