Specifications, Performance – John Wood Noritz N-069M_N-069S User Manual
Page 26
26
Item
Gas Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG : 194,000 btuh, LP : 194,000 btuh
45
°F Rise
6.9 Gal./min.
0.5-7.9 Gal./min.
100-150
°F (In 5°F intervals),
160, 170, 176
°F (14 Options)
120, 130, 140, 176
°F
(Original is 120
°F)
Maximum Performance
Minimum Performance
Specification
N-069M
Indoor/ Outdoor, Wall Hanging
Power Vented
Direct Ignition
15-150 PSI
0.5 GPM
23.6"(Height) x 13.8"(Width) x 9.4"(Depth)
46 lbs.
0.2 Gallon
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG : 71W
LP : 71W
Freeze Prevention 125W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Electric Leakage Prevention Device
(GFCI), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Remote Controller,
Remote Controller Cord,
Anchoring Screws
Specifications
Specifications
• Specifications may be changed without prior notice.
• The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
N-063S
44 lbs.
NG : 65W
LP : 65W
Freeze Prevention 125W
Anchoring Screws
NG : 25,000 btuh, LP : 25,000 btuh
6.3 Gal./min.
0.5-6.3 Gal./min.
120, 130, 140
°F
(Original is 120
°F)
N-069M
N-063S
(Using the remote controller)
100-150
°F (In 5°F intervals),
160
°F (12 Options)