beautypg.com

Remote controller, Connecting the remote, N-063s temperature options – John Wood Noritz N-069M_N-069S User Manual

Page 54: Remote controller cord, Connecting remote controller cord to unit

background image

54

1. Leave enough slack so that the remote controller

cord will not be damaged if the unit is removed from
the wall.

2. Remove the front cover of the heater (4 screws).
3. Pass the remote controller cord through the wiring

throughway and into the unit.

4. Connect the Y terminals at the end of the remote

controller cord to the terminal block.

5. Secure the remote controller cord with a clamp.
6. Replace the front cover.

18AWG Wire

Remote controller cord

• For extensions, a 26' cord can be purchased (Part # RC-CORD26) or use 18AWG wire.
• Install according to the National Electrical Code and all applicable local codes.

Connecting Remote Controller Cord to Unit

• Keep the remote controller cord away from the freeze prevention heaters in the unit.
• Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment.
• The remote controller cord can be extended up to 300' with 18AWG wire.
• Use a Y type terminal with a resin sleeve. (Without the sleeve, the copper wire may corrode and

cause problems).

• Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the

terminal block.

Clamp

Terminal
Block

Wiring
Throughways

Changing Set Temperature (Not using the remote controller for N-063S).

1. Disconnect power to the heater.
2. Remove the front cover of the heater (4 screws).

• To set the temperature to 130°F
Remove the connector with 130°F tag.
• To set the temperature to 140°F
Remove the connector with 140°F tag.

3. Replace the front cover of the heater (4 screws).
4. Reconnect power to the heater.

130

° F

Co

nne

cto

r

140

° F

Con

nec

tor

130°F tag

140°F tag