6.

Installation Clearances

Before installing, check for the following:

Install in accordance with relevant building and mechanical codes, as well as any local, state
or national regulations.

Caution

Item

Required Clearances

From Heater

• Maintain the following clearance from

both combustible and non-combustible
materials.

Check

Illustration

12" Indoor

36" Outdoor

24" Outdoor

4" Indoor

2" Indoor

24" Outdoor

• If possible, leave 8" or more on either

side of the unit to facilitate inspection.

• If possible, leave 24" or more in front of

the unit to facilitate maintenance
and service if necessary.

Securing of space for

repair/inspection

24" or

more

8" or

more

8" or

more

Min: 3"

Min: 3"

• If the unit will be installed in the vicinity of a

permanent kitchen range or stove that has
the possibility of generating steam that
contains fats or oils, use a dividing plate or
other measure to ensure that the unit is not
exposed to air containing such impurities.

* The dividing plate should be of noncombust-

ible material of a width greater than the
water heater.

Exhaust hood

Range

Dividing plate

Water
heater

(unit: inch)

Cooking Equipment