• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick

Connect Cord.

Typical Plumbing

The Quick Connect Cord is 6 ft. long. Install the units 2-18" apart from each other to ensure the

cord will be able to reach between the units. (See Typical Plumbing diagram).

(If the distance between the two units is too great, not only will the cord not be able to reach,

but the water temperature may also become unstable because of the difference in pipe length

between the two units).

* When connecting two units, use only a

single remote controller.

Note: Connect the remote

controller to only one
of the units.

System Diagram

• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the cold

water supply piping to prevent heat loss and freezing of pipes when exposed to excessively cold

temperatures.

G

Quick Connect

Cord

Remote Controller Cord

Gas Supply Piping

Cold Water Supply

Hot Water

Remote Controller

Terminal Block

Cord

Connector

Cord

Connector

Union

Make this distance as short as possible.

* The hot water temperature will

become unstable as the pipe

length increases.

Distance at center: 16-32 in.

Quick Connect

cord

Union

Gas Valve

Union

Shutoff
Valve

Shutoff Valve

Hot Water

Cold Water

Shutoff
Valve

Distance on sides

2-18 in.

Leave enough clearance around the plumbing to

apply insulation. It will be necessary to add

bends to the piping to ensure that this clearance

is available.

Size the piping to allow for the maximum

flow rates of the units.

Pressure

Relief

Valve