AT^IDTO

Data Forwarding Time Out

Description:

Defines the data gap time (in milliseconds x10) after which the iCE

3

will forward the data

packet to the remote destination. This mode should be used for binary data packets as used
by iQuest products and Campbell Scientific dataloggers.


Default:

20 (200ms)


Notes:

Range is 0-255 (0 -> 2.55 seconds). If this parameter is set to zero, then data will not be
forwarded unless a forwarding character is defined using the AT^IDFC command.

Mode

Command

Responses

Read

AT^IDTO?

^IDTO: 0
OK

Write

AT^IDTO=20

OK OR ERROR

Help

AT^IDTO=?

^IDTO: (0-255)
OK


6.3.7 AT^IGOL

Go On-Line

Description:

Manually initiates connection to the GPRS network. Normally used after a command mode
session where parameters have been viewed or edited and reconnection is required.


Default:

N/A


Notes:

This command is write only.

Mode

Command

Response

Write

AT^IGOL

Connecting…
OK



6.3.8 AT^IHDT

Host Device Type

Description:

Defines the type of device that is connected to the host (RS232) port. Refer to Section 4.2

for details on how each of these device types work and Section 7 for cable information for each.

Default:

0 (Normal)


Notes:

Range is 0-2 (0=Standard, 1=CSI datalogger, 2=Unidata datalogger)

Mode

Command

Responses

Read

AT^IHDT?

^IHDT: 0
OK

Write

AT^IHDT=0

OK OR ERROR

Help

AT^IHDT=?

^IHDT: (0-2)
OK