beautypg.com

Xylem iCE3 GPRS Variant User Manual

Page 16

background image

GPRS iCE

3

, V1.30 User Guide

12

iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857 0810 Fax: +64 7 857 0811 Email: [email protected]

6.3.1 AT^IACE

Auto-Connect Enable

Description:

Disables, enables or sets scheduled mode for the auto-connection feature.


Default:

0 (Disabled)


Notes:

If this parameter is set to zero, the GPRS connection must be initiated manually via the
AT^IGOL command. If set to one, the iCE

3

will maintain a permanent GPRS link

automatically and if set to two, the scheduled settings as defined by the AT^IACS command
are used to regularly connect and disconnect from the network.

Mode

Command

Responses

Read

AT^IACE?

^IACE: 0
OK

Write

AT^IACE=0

OK OR ERROR

Help

AT^IACE=?

^IACE: (0-2)
OK


6.3.2 AT^IACS

Auto-Connect Settings

Description:

Configures the auto-connection scheduled mode. See Section 5 for details on using this
feature.


Default:

0,0,0,0,0 (Disabled)


Notes:

This command sets up the parameters for the auto-connect scheduled mode (only
applicable when AT^IACE=2). The parameters are:

Start time in day

(HHMM)

e.g.

600

(6am)

End time in day

(HHMM)

e.g.

1800

(6pm)

Duration on-line

(in seconds)

e.g.

120

(2 minutes on-line)

Interval when inside time window

(in minutes)

e.g.

60

(every hour)

Interval when outside time window

(in minutes)

e.g.

0

(never)

Mode

Command

Responses

Read

AT^IACS?

^IACE: 0
OK

Write

AT^IACS=600,1800,120,60,0

OK OR ERROR

Help

AT^IACS=?

^IACS: (0,2359,300,60,0)
OK


6.3.3 AT^IAPN

Access Point Name

Description:

Defines the access point name to use for the connection to the GPRS network.


Default:

“”


Notes:

This parameter has a maximum length limit of 100 characters. For a selection of common
APNs, please refer to Section 3 (Installation).

Mode

Command

Responses

Read

AT^IAPN?

^IAPN: “iquest.co.nz”
OK

Write

AT^IAPN=”iquest.co.nz”

OK OR ERROR

Help

AT^IAPN=?

^IAPN: “APN”
OK