5 what to do if, What to do if -1, 5what to do if – YSI IQ SensorNet MIQ/IC2 Module User Manual
Page 19

MIQ/IC2
What to do if ...
5 - 1
ba76034e01
01/2012
5
What to do if ...
No measured value
Measurement provides
implausible measured
values
Display of OFL
Cause
Remedy
– MIQ/IC2 not connected
– Connect the MIQ/IC2
– Unknown
– Look in the log book
Cause
Remedy
– Unsuitable settings of:
– Measuring range,
– Display value (0/4 mA),
– Display value (20 mA)
– Adjust the settings in the setting
menu of the MIQ/IC2
– Current value at the current
input or output of an instru-
ment (e.g. measuring trans-
mitter, power supply/isolator,
MIQ/IC2 etc.) does not agree
with the nominal value
– Change the settings of the
external meters as necessary
– Adjust the settings in the setting
menu of the MIQ/IC2
– Calibration is not up-to-date
– Calibrate the external meter
Cause
Remedy
– Allowed signal range excee-
ded or undercut
– Operate the 0/4 ... 20 mA cur-
rent inputs of the MIQ/IC2 in the
allowed current range only (see
chapter 7 T
- 3100 (50 pages)
- 3200 (86 pages)
- 5000 (70 pages)
- 5200 (148 pages)
- 5200A (128 pages)
- 5200A (121 pages)
- 5400 (127 pages)
- 5239 Dissolved Oxygen Probe (23 pages)
- 55 (26 pages)
- 550A (18 pages)
- 556 MPS - Quick Start Guide (4 pages)
- 58 (40 pages)
- 5905 (22 pages)
- 6600V2 - User Manual (379 pages)
- 60 (33 pages)
- 63 (46 pages)
- 650 MDS (72 pages)
- 9300 Photometer (11 pages)
- 9500 Photometer (143 pages)
- 9500 Photometer (18 pages)
- CR 3200 Thermoreactor (42 pages)
- CR 4200 Thermoreactor (42 pages)
- CR2200 Thermoreactor (36 pages)
- DO200 (40 pages)
- EC300 (40 pages)
- EC300A (40 pages)
- EC30A (12 pages)
- IFL 700 IQ (46 pages)
- IQ SensorNet 2020 XT Terminal (196 pages)
- IQ SensorNet FDO Sensor (48 pages)
- IQ SensorNet MIQ/A-MOD Module (42 pages)
- IQ SensorNet MIQ/A-PR Module (36 pages)
- IQ SensorNet MIQ/IF232 Module (18 pages)
- IQ SensorNet MIQ/JB Module (18 pages)
- IQ SensorNet MIQ/JBR Module (20 pages)
- IQ SensorNet MIQ/PS Module (22 pages)
- IQ SensorNet MIQ/R6 Module (56 pages)
- IQ SensorNet NitraLyt Sensor (64 pages)
- IQ SensorNet SensoLyt Sensor 700 IQ (SW) (46 pages)
- IQ SensorNet Sensors Encoded Fieldbus Data (12 pages)
- IQ SensorNet TetraCon Sensor 700 IQ (SW) (32 pages)
- IQ SensorNet ViSolid Sensor 700 IQ (60 pages)
- MultiLab 4010-1 (108 pages)
- MultiLab 4010-2 (138 pages)