DEALER SER

VICE

If tr

ouble occurs that cannot be rectified, contact your local

B&G representative. He will need the following information in
order to give you assistance.

1. Complete nameplate data of pump and motor.

SEE RATING NAMEPLATE.

2. Suction and discharge pipe pressure gauge readings.

3. Vacuum readings.

4. Ampere draw of the motors.

5. A sketch of the pump hook-up and piping.

6. Complete information on boiler control switches and any

motorized or solenoid valves in the boiler feed piping.

Morton Grove, Illinois 60053

TM

TM

SERIES HV

MODEL

SERIAL

GPM

PSI

PUMP

CFM

IN HG.

PUMP

DWGS

POWER V.

PH.

HZ 60

CONTROL V.

PH. 1

HZ 60

TOTAL

LARGEST MOTOR

F.L. AMP

F.L. AMP

DN0016

18. Install diffuser.

19. Install propeller and tighten set screws.

20. Using new gasket and noting alignment pin, install assembly on

suction housing.

21. Install suction housing and discharge fasteners and tighten.

22. Reconnect pump bleed line and motor wiring.

23. Close drain and slowly open inlet valves. See warning.

24. Jog to check motor rotation. See caution.

25. Observe operation thru several cycles.

W

ARNING: EXPLOSIBLE

Do not pr

essurize receiver. Isolate receiver during leak test.

Do not plug overflow. Do not restrict vent opening to atmosphere.
Open valves slowly. Failure to follow these instructions could result
in serious injury or death.

CAUTION:

DO NOT REVERSE

Reverse operation can cause extensive damage to pumps.

Jog the motor to test for direction of rotation. Failure to follow these
instructions could result in serious injury or death.

CAUTION:

DO NOT RUN DRY.

SEAL DAMAGE MAY OCCUR

Inspect pump seal r

egularly for leaks Replace as required.

Failure to follow these instructions could result in serious injury or
death.