ME Subsystem Configuration
System Acoustic & Performance Configuration
Parameter
Description
Options
ME-HECI
Support
Select Enabled to enable ME-HECI (Host
Embedded Controller Interface) support,
which will allow the Host OS to
communicate directly with the
Management Engine (ME) in a standard
method for system management,
effectively replacing the SMbus.
Enabled
Disabled
Parameter
Description
Options
Throttling -
Closed Loop
Throttling improves reliability and
reduces power consumption in the
processor by automatic voltage control
during processor idle states.
Enabled
Disabled
Hysteresis
Temperature
(Available
when Closed
Loop is
enabled.)
Temperature Hysteresis is the
temperature lag (in degrees Celsius)
after the predefi ned DIMM
temperature threshold is reached before
Closed Loop Throttling begins.
Disabled
1.5
o
C
3.0
o
C
6.0
o
C
Guardband
Temperature
(Available
when Closed
Loop is
enabled.)
This is the temperature that applies to the DIMM
temperature threshold. Each step is in 0.5
o
C increments.
The default is [006]. Press <+> or <-> on your keyboard to
change this value.
Inlet
Temperature
This is the temperature detected at the chassis inlet. Each
step is in 0.5
o
C increments. The default is [070].
Temperature
Rise
This is the temperature rise to the DIMM thermal zone.
Each step is in 0.5
o
C increments. The default is [020].
Air Flow
This is the air fl ow speed to the DIMM modules. Each step
is one mm/sec. The default is [1500].