Ah5792, Functional block diagram, Operating – Diodes AH5792 User Manual
Page 3
AH5792
SINGLE PHASE HALL EFFECT LATCH SMART
FAN MOTOR CONTROLLER
AH5792
Document number: DS314641 Rev. 6 - 2
3 of 10
July 2010
© Diodes Incorporated
Functional Block Diagram
Frequency
Generator
Lock
Detector
Full Bridge
Driver
Hall
Sensor
AMP
V
dd
FG
O1
O2
Power
V
SS
Logic
Block
Operating
(Note 3, 4, 5)
FG
Out 2
Out 1
Ton
Toff
“Re-start spinning”
motor locked cleared
motor locked detected
Mechanical lock
Magentic
S
N
Normal spinning
Notes:
3. In “Normal spinning, the FG shall change its state at each rising edge of OUT2. In “Mechanical lock”, the FG state is kept as the
same as the moment of motor locked detected.
4. When magnetic is locked as “S” pole, then out1 is kept on “L”, out2 is a clock with Ton/Toff ratio. When magnetic is locked at
“N” pole, then out 2 is kept on “L”, out 1 is a clock with Ton/Toff ratio.
5. When “Re-start spinning” occurs, the motor shall ramp up to the “Normal Spinning” speed from zero. It depends on the motor
characteristics.