Sata configuration options, Scsi configuration options – Asus Adaptec 2025 ZCR User Manual
Page 77

A-12
Adaptec RAID Configuration Utility (ARC)
SATA Configuration Options
The SATA Configuration options are described in the table below.
SCSI Configuration Options
To access the SCSI Device Configuration options, select SCSI
Configuration
.
SCSI Channel Interface Definitions
The SCSI Channel Interface Definitions are described in the table
below.
Option
Default
Models
Affected
Description
Write Cache
Yes
All SATA
controllers
When Enabled, write cache is enabled,
providing maximum performance.
Caution
—When Enabled, there is a
potential for data loss or corruption
during a power failure.
Option
Default
Description
Controller SCSI
Channel ID
7
Sets the controller’s SCSI ID. Adaptec
recommends that you leave the controller set
to the default, which gives it the highest
priority on the SCSI channel.
SCSI Parity
Checking
Enabled
Determines whether the controller verifies
the accuracy of data transfer on the SCSI
channel. You should disable SCSI Parity
Checking on the controller and all SCSI
devices if any SCSI device supported by the
controller does not support SCSI parity;
otherwise, retain the default. Most SCSI
devices do support SCSI parity. If you are not
sure whether a device supports SCSI parity,
consult the documentation for the device.
Controller SCSI
Channel
Termination
Auto
Mode
Sets termination on the controller. Adaptec
recommends that you retain the default
setting.