8 enabling writecache, Enabling writecache -23 – Asus TS700-E6/RS8 User Manual
Page 131
ASUS TS700-E6/RS8
6-23
6.2.8
Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a
RAID set to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs
while transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCache
1. From the Management Menu, select Objects > Adapter, and then press
2. Select Disk WC, and then press
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
Adapter
Virtual Drive
Physical Drive
Adapter 0
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate = 30
BGI Rate = 30
Disk WC = Off
Read Ahead = On
Bios State = Enable
Stop On Error = No
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version A.08.09161344R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
5. When finished, press any key to continue.
3. From the Management Menu, select Objects > Virtual Drive, and then press
4. Select Disk WC, and then press
Management Menu
C o n f i g u r e
I n i t i a l i z e
O b j e c t s
R e b u i l d
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
A d a p t e r
V i r t u a l D r i v e
Physical Drive
Virtual Drive
R A I D = 0
Size = 1428604MB
Stripe Size = 64KB
# S t r i p e s = 2
State = OPTIMAL
S p a n s = 1
D i s k W C = O n
Read Ahead = On
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version A.08.09161344R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option