beautypg.com

Operation, Appendix – OSRAM EASY RMC User Manual

Page 2

background image

Page 2 of 2

Operation

Note

For the function of the DALI EASY III and OT EASY 60 II control

units, see the separate instructions.

DIP switch positions

The following settings can be made using the DIP switches (E):

DIP switch

Function

1

OFF

IR coding 1 is active

1

ON

IR coding 2 is active

2

OFF

Scene storage is disabled

2

ON

Scene storage is enabled

3

OFF

Sequence mode is disabled

3

ON

Sequence mode is enabled

4

OFF

Daylight simulation is disabled

4

ON

Daylight simulation is enabled

3/4 ON/ON

Learn mode for transmitting the

IR coding and resetting the con-

trol units to the factory settings
(RESET)

Setting the infrared coding / RESET

The two infrared codings make it possible to operate two

separate lighting control units in one room using a single remote

control without mutual interference. The control unit is returned

to the factory setting by means of a RESET or by changing the
infrared coding.



Disconnect control units whose infrared coding should not

be reset or adjusted from the mains supply or interrupt the

connection to the IR receiver.

‚

Set the desired infrared coding via the DIP switch of the
remote control:

DIP switch 1 = OFF:
infrared coding 1 is active

DIP switch 1 = ON:
infrared coding 2 is active

ƒ

Note the positions of DIP switches 3 and 4.

„

Set DIP switches 3 and 4 to ON.

…

Point the remote control to the infrared receiver and press
any button.
Confirmation:

„LS“ appears in the display and the luminaires flash.

– 1x for infrared coding 1

– 2x for infrared coding 2

†

Set DIP switches 3 and 4 to the original positions, reconnect

all control units to the mains supply and reconnect the IR
receiver.

Appendix

Technical data

Power supply

2 Micro AAA / LR03 batteries (alkaline)

Infrared signal

Interference-immune 38 kHz Rmap pro-

tocol, digital coded. 2 OSRAM-specific
codings are selectable.

Range

Approx. 10 – 15 m

Operating
temperature

0 °C ... +40 °C

Protection type

IP 20

Dimensions
(L x W x H)

120 x 57 x 26 mm

Conformity with the relevant EU directives is

confirmed by the CE symbol.