Wiring diagram, Mounting hints – OSRAM Touch DIM PD LI 2P WOS User Manual
Page 2
Page 2
OSRAM - operating instructions: TOUCH DIM PD LI 2P WOS
Wiring diagram
Mounting hints
The sensor is connected to a 3 wire cable which is admitted for mains voltage. Parallel connection of
several sensors is not allowed. The sensor is typically installed in luminaires, ceiling installation is
possible by use of a flush device box and an adequate cover.
Following sensor heads are approved to be used with the Touch DIM PD LI 2P WOS sensor:
(-> sensor head not included in delivery)
PANASONIC NaPiOn sensors (passiv infrared)
Digital version
- Standard type Standard
anthracite
AMN11111
(5m range)
white
AMN11112
Economy
anthrazit AMN31111
white
AMN31112
- Type for small movements
Standard
anthracite
AMN12111
white
AMN12112
Economy
anthracite
AMN32111
white
AMN32112
- Spot type
Standard anthracite AMN13111
white
AMN13112
Economy
anthracite
AMN33111
white
AMN33112
- 10m type
Standard
anthracite
AMN14111
white
AMN14112
Economy
anthracite
AMN34111
white
AMN34112
When adding a sensor head to the sensor, please note the following:
• The entire workplace must lie within the monitoring cone of the sensor.
• The sensor must not be exposed to drafts (e.g. near air vents). A draft could be misinterpreted as
the presence of a person in the room.
ECG QTi DALI
Lamp
1
2
3
4
DA
DA
~
~
ECG QTi DALI
Lamp
1
2
3
4
DA
DA
~
~
N
PE
Push button
(manual
control)
L
TOUCH DIM
Sensor
ECG QTi DALI
Lamp
1
2
3
4
DA
DA
~
~
ECG QTi DALI
Lamp
1
2
3
4
DA
DA
~
~
max. 4
QTi ECG
or HTi
transform
ers
L N S
signal wire length max. 10m
Push button and sensor have to be
connected to the same mains phase!