Operation (cont.)

Pure sequence mode operation
Short or long press: The corresponding sequence is started or

stopped.

On

T 1...4

Start sequence mode with sequence A..D

T 5

All luminaires: change brightness manually/switch

on and off

T 6

Resume paused sequence

T 7

Pause running sequence

T 8

Call up the next lighting scene

Light scenes and sequence mode operation

On

T 1...4

Store and call up lighting scenes 1...4

T 5

All luminaires: change brightness manually/switch

on and off

T 6

Start sequence mode with sequence A/resume

paused sequence

T 7

Pause running sequence

T 8

Call up the next lighting scene

Operation via switches or motion detector

Lighting scene operation
Close switch contact:

lighting scenes 1...15 are called up (depending on the DIP

switch setting).
Open switch contact:

lighting scene 16 is called up (default setting: all luminaires off).
For the unit to function effectively, only one of the contacts on

inputs T1 to T8 may be switched at any one time.

Push-

button

On

On

T 1...7

Store and call up ligh-

ting scenes 1...7

Store and call up ligh-

ting scenes 9...15

T 8

Call up lighting scene 8

Sequence mode operation
Close switch contact:

sequence A..D is started
Open switch contact:

lighting scene 16 is called up (default setting: all luminaires off).

Push-

button

On

T 1...4

Start sequence mode with sequence A..D

T 5...8

Appendix

Technical data

Outputs

EASY signal, 4-pin, SELV
• Max. 50 m line length to the next

control unit

• Max. 100 m total line length

Inputs

8 inputs for potential-free closer

contacts,max. 25 m line length at one

input,max. 50 m total line length over

all inputs

Leads diameter

0.25 …1.5 mm²

Operating tempe-

rature

0 °C …+ 50 °C

Protection type

IP 20

Protection class

III

Dimensions

(L x W x H)

47 x 44 x 13 mm

LED message

Communication: LED flashes

The CE requirements are fulfilled: EMC requirements as per

EN 61547, low voltage as per EN 60928.

Conformity with the relevant EU directives is

confirmed by the CE symbol.