Troubleshooting installation problems, For problems during installation, see the section, In chapter 2 – SENA Serial_IPTM Redirector 4.3 User Manual
Page 24: 7 troubleshooting installation problems

2.1
2.2
2.3
Running the Serial/IP Setup Program
2.4
2.5
Configuring Serial/IP COM Ports in the Control Panel
2.6
Using the Serial/IP Configuration Wizard
2.7 Troubleshooting Installation Problems
2.7 Troubleshooting Installation Problems
Please note the following suggestions regarding installation problems:
●
If your license key is not accepted when you enter it, click
●
Are you using correct values for both IP Address of Server and TCP Port Number?
A common mistake is to assume the TCP port number is the "device number" on the server. TCP port
numbers start at a large number, usually 4000 or higher. Note: Any TCP port number less than 1024 is
almost always wrong. See Appendix D
for ways to debug this type of problem.
●
Are your settings for Credentials matching what the serial server expects?
The Log display in the Configuration Wizard will show authentication problems with serial server login.
●
Is the serial server providing a serial port on the expected TCP Port Number?
Serial servers differ in the methods used to make serial ports available to the network on a TCP port.
●
Are errors appearing in the Log display of the Configuration Wizard?
For detailed information and tips, see Appendix C
2. Installing the Serial/IP Redirector