beautypg.com

Special application fuses, 482 series alarm indicating fuse holder, Dimensions – Littelfuse 482 Series User Manual

Page 3

background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.
Revised: 12/19/13

Special Application Fuses

482 Series Alarm Indicating Fuse Holder

Dimensions

FEMALE LATCHING & FLUSH SIDE

WITHOUT TABS

TYPICAL HOLDER ASSEMBLY

21.3mm

(.84")

TYP

6.4mm

(.25")

TYP

A

18.5mm

(.73")

12.4mm

(.49")

1.6mm

(.062")

TYP

4.1mm

(.16")

TYP

19.8mm

(.78" )

TYP

.03

6.4mm

(.250")

.005

10.7mm

(.420")

.005

6.4mm

(.250")

.005

Ø 2.3mm HOLES

(.090")

(3 HOLES)

RECOMMENDED P. C. BOARD

MOUNTING HOLES

Alarm Terminal

FEMALE LATCHING & FLUSH SIDE

WITHOUT TABS

TYPICAL HOLDER ASSEMBLY

21.3mm

(.84")

TYP

6.4mm

(.25")

TYP

A

18.5mm

(.73")

12.4mm

(.49")

1.6mm

(.062")

TYP

4.1mm

(.16")

TYP

19.8mm

(.78" )

TYP

.03

6.4mm

(.250")

.005

10.7mm

(.420")

.005

6.4mm

(.250")

.005

Ø 2.3mm HOLES

(.090")

(3 HOLES)

RECOMMENDED P. C. BOARD

MOUNTING HOLES

Alarm Terminal

FEMALE & MALE LATCHING

WITH TABS

FEMALE & MALE LATCHING

WITH TABS AND NO MOUNTING HOLES

FEMALE LATCHING & FLUSH SIDE

WITH TABS

37.1mm

(1.46")

6.4mm

(.25")

A

0.6mm

(.025")

TYP

1.6mm

(.062")

TYP

15.7mm

(.62")

9.0mm (.355")

18.5mm

(.73" )

.010

12.4mm

(.49" )

.010

24.9mm

(.98" )

.03

21.3mm

(.84")

30.9mm (1.215")

30.7mm (1.210")

TYPICAL HOLDER ASSEMBLY

21.8mm

(.86" )

.005

6.9mm

(.27" )

.005

30.9mm (1.215")

30.7mm (1.210")

Ø 4.1mm

(.160")

MOUNTING HOLE

(2 HOLES)

TYPICAL CUT-OUT IN

PANEL OR CHASSIS

6.4mm

(.25")

21.8mm

(.86" )

.005

6.9mm

(.27" )

.005

6.4mm

(.25")

RECOMMENDED PANEL

MOUNTING HOLES

30.9mm (1.215")

30.7mm (1.210")

30.9mm

(1.212")

Ø 4.1mm

(.160")

MOUNTING HOLE

(2 HOLES)

TYPICAL CUT-OUT IN

PANEL OR CHASSIS

.150''

DIA,

(2 Holes)

21.34mm (.84")

(1.47")

37.34mm

0.6mm

(.025")

TYP

1.6mm

(.062")

TYP

15.7mm

(.62")

9.0mm (.355")

18.5mm

(.73" )

.010

12.4mm

(.49" )

.010

24.9mm

(.98" )

.03

21.3mm

(.84")

6.4mm

(.25")

NOTE: The 20 ampere single pole holder is designed to
accept all fuse ratings up to 20 amperes.
20 ampere fuseholders should be spaced 12.7mm
(0.50) apart when loaded to maximum capacity, center
to center to insure proper heat dissipation under normal
operation.
Heatsinking may be required for operation in higher
ambient temperatures or alternate configurations.

15A pCb mount Series:

15A panel mount Series:

20A panel mount Series: