beautypg.com

Tvs diode arrays, Lightning surge protection - sp3304n series, Diodes) – Littelfuse SP3304N Series User Manual

Page 2

background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.

Revised: 04/24/13

TVS Diode Arrays

(SPA

®

Diodes)

Lightning Surge Protection - SP3304N Series

CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause
permanent damage to the device. This is a stress only rating and operation of the device
at these or any other conditions above those indicated in the operational sections of this
specification is not implied.

Absolute Maximum Ratings

Symbol

Parameter

Value

Units

I

PP

Peak Current (t

p

=8/20μs)

20.0

A

P

PK

Peak Pulse Power (t

p

=8/20µs)

300

W

T

OP

Operating Temperature

–40 to 125

ºC

T

STOR

Storage Temperature

–55 to 150

°C

Electrical Characteristics

(T

OP

=25ºC)

Parameter

Symbol

Test Conditions

Min

Typ

Max

Units

Reverse Standoff Voltage

V

RWM

3.3

V

Punch Through Voltage

V

PT

I

PT

=5µA

3.5

V

Snap Back Voltage

V

SB

I

SB

=50mA

2.8

V

Reverse Leakage Current

I

LEAK

V

R

=2.5V, I/O to GND

0.5

1.0

µA

Clamp Voltage

1

V

C

I

PP

=1A, t

p

=8/20µs, Fwd

6.0

V

I

PP

=5A, t

p

=8/20µs, Fwd

7.0

V

I

PP

=10A, t

p

=8/20µs, Fwd

8.0

V

I

PP

=20A, t

p

=8/20µs, Fwd

11.5

V

Dynamic Resistance

R

DYN

(V

C2

-V

C1

)/(I

PP2

-I

PP1

)

0.25

W

ESD Withstand Voltage

1

V

ESD

IEC61000-4-2 (Contact)

±30

kV

IEC61000-4-2 (Air)

±30

kV

Diode Capacitance

1

C

I/O-GND

Reverse Bias=0V

3.5

5.0

pF

Diode Capacitance

1

C

I/O-I/O

Reverse Bias=0V

2.0

pF

Note:

1.

Parameter is guaranteed by design and/or device characterization.

Thermal Information

Parameter

Rating

Units

Storage Temperature Range

–55 to 150

°C

Maximum Junction Temperature

150

°C

Maximum Lead Temperature

(Soldering 20-40s)

260

°C

Clamping Voltage vs. I

PP

Pulse Waveform

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

110%

0.0 5.0 10.0 15.0 20.0 25.0 30.0

Time (μs)

Percent of

I

PP

0 5 10 15 20

Peak Pulse Current-I

PP

(A)

0.0

2.0

4.0

6.0

10.0

12.0

Clamp Voltage (V

C

)

8.0