beautypg.com

Axial lead & cartridge fuses, Pico – Littelfuse 267 Series PICO User Manual

Page 3

background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.

Revised: 12/19/13

Axial Lead & Cartridge Fuses

PICO

®

> Very Fast Acting > 265/266/267 Series

Materials

Body: White Thermoplastic

Gold-Plated Copper Leads, Type II

Weight

.32 Grams

Solderability MIL-STD-202, Method 208

Lead Pull
Force

MIL-STD-202, Method 211, Test Condition A (will

withstand a 5 lbs. axial pull test)

AQL (Electrical Characteristics): Certified to 1%

AQL

Sampling

Per MIL-STD-105, Inspection Level II.

Traceability and Identification Records: Controlled

by lot number and retained on file for a minimum

of three years. Copies of Lot Certification Test

data available when requested with order

Options

Special screening tests, burn-in, etc. can be

supplied on special order to meet specific

requirements. For information on higher current

ratings, contact Littelfuse.

267 series fuses are offered with optional solder

coated leads. To order, enter XT as the end suffix

(see Part Numbering System section)

Product Characteristics

Operating Temperature –55ºC to +125ºC

Shock

MIL-STD-202, Method 213, Test

Condition I (100 G’s peak for 6

milliseconds).

Vibration

MIL-STD-202, Method 201 (10–55

Hz); MIL-STD-202, Method 204, Test

Condition C (55–2000 Hz at 10 G’s

Peak)

Salt Spray

MIL-STD-202, Method 101, Test

Condition B

Seal Test

MIL-STD-202, Method 112, Test

Condition A

Insulation Resistance
(After Opening)

MIL-STD-202, Method 302, Test

Condition A (1/2 Megohm minimum)

Thermal Shock

MIL-STD-202, Method 107, Test

Condition B (–65°C to 125

°

C).

Moisture Resistance

MIL-STD-202, Method 106

Fuses To MIL SPEC

265 Series (except 1/16 ampere

rating) is available in FM08A on QPL

for MIL-PRF-23419/8. To order, change

265 to 267

3/4 A

3/4 A

Transparent

Insulating Sleeve

Transparent

Insulating Sleeve

(1.50")

(1.50")

7.11

(.28")

7.11 (.28")

2.36 (.093")

DIA.

2.36 (.093")

DIA.

90

8.38 (.33) (Note 1)

37.33

(1.47")

(Note 1: 9.14 (.36") for 15 amp rating)

265 000 Series

266 000 Series

38.1

38.1

Dimensions

Packaging

packaging Option

Quantity

Quantity &

packaging Code

Bulk Pack

5

V

Part Numbering System

0267 xxxx V XT

Quantity & Packaging Code

Lead Option Code

Amp Code

Series

Refer to Amp Code column of

Electrical Characteristics Table

V = (All series) 5 quantity bulk pack

Blank = (All series) standard lead

XT = (267 series only) solder coated lead option

Additional Information

Datasheet

Samples

Resources

Datasheet

Samples

Resources

Datasheet

Samples

Resources

265 Series

266 Series

265 Series

266 Series

265 Series

266 Series

267 Series

267 Series

267 Series