Surface Mount Fuses

159 Fuse and Clip Series

GR 1089 AC power fault 1st level inter-building (fuse
not allowed to open)

GR 1089 AC power fault 2nd level (fuse can open but
must open in a safe and controlled manner)

Test

Vrms

Short

Circuit

Current (A)

Hits Duration primary

protector

Fuse

Choices

1

50

.33

1

15 min.

removed 1.25, 2.0

2

100

.17

1

15 min.

removed 1.25, 2.0

3

200,400,

600

1

60

1 sec.

removed 1.25, 2.0

4

1000

1

60

1 sec.

operative 1.25, 2.0

5

Diagram

Diagram

60

5 secs.

removed 1.25, 2.0

6

600

0.5

1

30 secs. removed 1.25, 2.0

7

440

2.2

5

2 secs.

removed 1.25, 2.0

8

600

3

1

1.1 secs. removed 1.25, 2.0

9

1000

5

1

0.4 sec.

in place

1.25, 2.0

Test

Circuite

Vrms

Short

(A)

Duration

Fuse

1

120,277

25

15 min.

0.5, 1.25, 2.0

2

600

60

5 secs.

0.5, 1.25, 2.0

3

600

7

5 secs.

0.5, 1.25, 2.0

4

100-600

2.2

15 min..

0.5, 1.25, 2.0

5

Diagram

Diagram

15 min.

0.5, 1.25, 2.0

Fuse must open before wiring simulator fuse (MDL 2.0).

Test

Number

Voltage (V) Current (A)

Time

Fuse

Choices

L1

600

40

1.5 secs.

0.5, 1.25, 2.0

L2

600

7

5 secs.

0.5, 1.25, 2.0

L3

600

2.2

30 min.

0.5, 1.25, 2.0

L4

200

2.2

30 min.

0.5, 1.25, 2.0

L5

120

25

30 min.

0.5, 1.25, 2.0

M1

600

40

1.5 secs.

0.5, 1.25, 2.0

M2

600

7

5 secs.

0.5, 1.25, 2.0

M3

600

2.2

30 min.

0.5, 1.25, 2.0

M4

600

2.2

30 min.

0.5, 1.25, 2.0

Selection of test number depends on current limiting F fire enclosure/spacing of end product
• 26 AWG line cord removes L1/M1 test requirement
• L5 conducted only if product does not pass section 6.1.2
• L2,M2,L3,M3,L4,M4 conducted if not in a fire enclosure
Fuse must open before the wiring simulator fuse (MDL 2.0).

UL60950 Requirements

Test

Voltage

(V)

Current

(A)

Waveform

Repeti-

tions

Fuse

Choices

Impulse

For

handheld

units

2500

62.5

10×700ms + 10 w/60

secs. rest

0.5, 1.25,

2.0

Non

handheld

1500

37.5

10×700ms + 10 w/60

secs. rest

0.5, 1.25,

2.0

Steady-State

For

handheld

units

1500

60Hz

0.5, 1.25,

2.0

Non

handheld

1000

60Hz

0.5, 1.25,

2.0

GR 1089 Inter-building requirements

GR 1089 1st level lighting surge inter-building
(Equipment under test can not be damaged and must
continue to operate properly)

Surge

minimum

peak

Voltage

(V)

minimum

peak

Current

(A)

max.

Rise/min.

Decay

(µs)

Repetitions

each

polarity

Fuse

Choices

1

600

100

10/1000

25

1.25, 2.0

2

1000

100

10/360

25

1.25, 2.0

3

1000

100

10/1000

25

1.25, 2.0

4

2500

500

2/10

10

1.25, 2.0

5

1000

25

10/360

5

0.5, 1.25, 2.0

GR 1089 2nd level lightning surge telecom port
(Equipment under test shall not become a fire,
fragmentation, or electrical safety hazard)

Surge

minimum

peak

Voltage

(V)

minimum

peak

Current (A)

max.

Rise/min.

Decay

(µs)

Repe-

titions

each

polarity

Fuse

Choices

1

5000

500

2/10

1

0.5, 1.25, 2.0

Alter-

native

5000

500/8=625

8/10

1

0.5, 1.25, 2.0

If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4.

The 0.5 fuse will open during these test conditions. The 1.25 & 2.0 will not open thus
providing operational compliance.

UL 60950 (EN 60950, formerly UL 1950) Power Cross Test
(L=Longitudinal, M=Metallic)

UL 60950 (EN 60950, formerly UL 1950) Impulse Test
and Steady-State Electric Strength Test