Surface mount fuses, 159 fuse and clip series – Littelfuse 159 Series User Manual
Page 3
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13
Surface Mount Fuses
159 Fuse and Clip Series
GR 1089 AC power fault 1st level inter-building (fuse
not allowed to open)
GR 1089 AC power fault 2nd level (fuse can open but
must open in a safe and controlled manner)
Test
Vrms
Short
Circuit
Current (A)
Hits Duration primary
protector
Fuse
Choices
1
50
.33
1
15 min.
removed 1.25, 2.0
2
100
.17
1
15 min.
removed 1.25, 2.0
3
200,400,
600
1
60
1 sec.
removed 1.25, 2.0
4
1000
1
60
1 sec.
operative 1.25, 2.0
5
Diagram
Diagram
60
5 secs.
removed 1.25, 2.0
6
600
0.5
1
30 secs. removed 1.25, 2.0
7
440
2.2
5
2 secs.
removed 1.25, 2.0
8
600
3
1
1.1 secs. removed 1.25, 2.0
9
1000
5
1
0.4 sec.
in place
1.25, 2.0
Test
Circuite
Vrms
Short
(A)
Duration
Fuse
1
120,277
25
15 min.
0.5, 1.25, 2.0
2
600
60
5 secs.
0.5, 1.25, 2.0
3
600
7
5 secs.
0.5, 1.25, 2.0
4
100-600
2.2
15 min..
0.5, 1.25, 2.0
5
Diagram
Diagram
15 min.
0.5, 1.25, 2.0
Fuse must open before wiring simulator fuse (MDL 2.0).
Test
Number
Voltage (V) Current (A)
Time
Fuse
Choices
L1
600
40
1.5 secs.
0.5, 1.25, 2.0
L2
600
7
5 secs.
0.5, 1.25, 2.0
L3
600
2.2
30 min.
0.5, 1.25, 2.0
L4
200
2.2
30 min.
0.5, 1.25, 2.0
L5
120
25
30 min.
0.5, 1.25, 2.0
M1
600
40
1.5 secs.
0.5, 1.25, 2.0
M2
600
7
5 secs.
0.5, 1.25, 2.0
M3
600
2.2
30 min.
0.5, 1.25, 2.0
M4
600
2.2
30 min.
0.5, 1.25, 2.0
Selection of test number depends on current limiting F fire enclosure/spacing of end product
• 26 AWG line cord removes L1/M1 test requirement
• L5 conducted only if product does not pass section 6.1.2
• L2,M2,L3,M3,L4,M4 conducted if not in a fire enclosure
Fuse must open before the wiring simulator fuse (MDL 2.0).
UL60950 Requirements
Test
Voltage
(V)
Current
(A)
Waveform
Repeti-
tions
Fuse
Choices
Impulse
For
handheld
units
2500
62.5
10×700ms + 10 w/60
secs. rest
0.5, 1.25,
2.0
Non
handheld
1500
37.5
10×700ms + 10 w/60
secs. rest
0.5, 1.25,
2.0
Steady-State
For
handheld
units
1500
60Hz
0.5, 1.25,
2.0
Non
handheld
1000
60Hz
0.5, 1.25,
2.0
GR 1089 Inter-building requirements
GR 1089 1st level lighting surge inter-building
(Equipment under test can not be damaged and must
continue to operate properly)
Surge
minimum
peak
Voltage
(V)
minimum
peak
Current
(A)
max.
Rise/min.
Decay
(µs)
Repetitions
each
polarity
Fuse
Choices
1
600
100
10/1000
25
1.25, 2.0
2
1000
100
10/360
25
1.25, 2.0
3
1000
100
10/1000
25
1.25, 2.0
4
2500
500
2/10
10
1.25, 2.0
5
1000
25
10/360
5
0.5, 1.25, 2.0
GR 1089 2nd level lightning surge telecom port
(Equipment under test shall not become a fire,
fragmentation, or electrical safety hazard)
Surge
minimum
peak
Voltage
(V)
minimum
peak
Current (A)
max.
Rise/min.
Decay
(µs)
Repe-
titions
each
polarity
Fuse
Choices
1
5000
500
2/10
1
0.5, 1.25, 2.0
Alter-
native
5000
500/8=625
8/10
1
0.5, 1.25, 2.0
If sufficient series resistance is used, then the 0.5 fuse may be used in test conditions 1-4.
The 0.5 fuse will open during these test conditions. The 1.25 & 2.0 will not open thus
providing operational compliance.
UL 60950 (EN 60950, formerly UL 1950) Power Cross Test
(L=Longitudinal, M=Metallic)
UL 60950 (EN 60950, formerly UL 1950) Impulse Test
and Steady-State Electric Strength Test