Specifications

B9300 Power Reference Unit

Max. voltage

480V

Voltage range

90 - 120%

Consumption

2VA at U

N

DC output

0 - 1V DC, ±1V DC, 0 - 3V DC or 0 - 5V DC

Operating temperature

-20 to +70°C

EMC

CE according to EN50081-1, EN50082-1, EN50081-2,

EN50082-2

Burn-in

50 hours before final test

Weight

0.7kg

Dimensions

96 x 96 x 80mm (H x W x D)

Panel cut out

92 X 92mm (H x W)

The specifications are subject to change without notice.

Type Selection Table

Terminals

Type

1-2

Function

B9300.0010

220-240V

Output 0 - 1V DC

B9300.0030

220-240V

Output 0 - 3V DC, to be used with T4300/T4400-xx

B9300.0040

220-240V

Output 0 - 3V, to be used with T4300/T4400-xx,

max. adjustment from 1.5 - 3V DC

B9300.0050

100-110V

Output 0 - 1V DC

B9300.0060

380-450V

Output 0 - 1V DC

B9300.0070

380-450V

Output ±1V DC

B9300.0090

415-480V

Output 0 - 1V DC

Other voltages and combinations are available on request.