Surface mount fuses, Average time current curves, Soldering parameters temperature rerating curve – Littelfuse 446 Series User Manual
Page 2
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13
Surface Mount Fuses
EBF Fuse Fast-Acting > 446/447 Series
Materials
Body: Plastic Body – Terminations: Tin-load
(95/5) plated Zn, Ni barrier
Cleaning
No-cleaning process recommended
Operating
Temperature
–40
O
C to 125
O
C
Product Characteristics
Dimensions
Packaging
Part Numbering System
PATA6
04
602
LF
350V
10.92
(.430")
8.76
(.345")
(.032")
0.81
(.295")
7.49
1.50 (.059") MAX
3.2 (.126")
0.81
(.032")
3.2
(.126")
5.59
(.220")
3.81
(.150")
1.52
(.060")
1.44
(.057")
5.91
(.233")
8.81
(.347")
4.03
(.159")
1.27
(.050") Dia
10.11
(.398")
Reference Dimensions
(Inches)
Recommended
Pad Layout
447 Mounting
Holes
Average Time Current Curves
1000
100
10
1
0.1
0.01
1000
100
10
1
0.1
2A
3A 4A 5A 7 1/2A 10A
TIME IN SECONDS
CURRENT IN AMPERES
Soldering Parameters
Temperature Rerating Curve
Note:
1. Derating depicted in this curve is in addition to the standard derating of 25% for
continuous operation.
For 447 dimensions, please contact Littelfuse for specifications.
446 Series:
Reflow Solder — 235°C, 5 seconds maximum.
No-clean process recommended.
Wave Solder — Not recommended.
Non-plated terminal surfaces may not meet
MIL-STD-202, Method 208.
447 Series:
Contact Littelfuse for soldering parameters.
Inside terminal face of each lead is non-plated zinc.
Non-plated zinc terminal faces may not meet MIL-STD-202,
method 208. To ensure that the fuse is acceptable for the
application, appropriate application testing should be performed.
packaging
Option
packaging
Specification
Quantity
Quantity &
packaging Code
446 Series
24mm Tape
and Reel
EIA RS-481-1
(IEC 286, part 3)
800
ZRP
447 Series
Bulk Pack
–
4000
YXP
0446 002. ZRP
Series
Amp Code
Quantity Code
ZRP = 800
0447 002. YXP
Series
Amp Code
Quantity Code
YXP = 4000
Surface Mount Fuses:
Through Hole Fuses: