Littelfuse 223 Series User Manual
5 x 20 mm, Axial lead and cartridge fuses, Designed to iec standard

Designed to IEC Standard
Axial Lead and Cartridge Fuses
5 x 20 mm
Time Lag Fuse (Slo-Blo
®
Fuse) 218/213 Series
295
w w w . l i t t e l f u s e . c o m
8
AXIAL LEAD AND
CAR
TRIDGE FUSES
10A
15A
8A
6.3A
5A
4A
3.15A
2.5A
2A
1.6A
1.25A
1A
.800A
.630A
.500A
.400A
.315A
.250A
.200A
.160A
.125A
.100A
.080A
.063A
.050A
.040A
.032A
500
100
10
1
0.1
0.05
0.001
0.01
0.1
1
10
100
TIME IN SECONDS
CURRENT IN AMPERES
Average Time Current Curves for 218/228
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.032 to 10 amperes.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Ampere
Opening
Rating
Rating
Time
150%
.032 – .100
60 minutes, Minimum
.125 – 6.3
60 minutes, Minimum
210%
.032 – .100
2 minutes, Maximum
.125 – 6.3
2 minutes, Maximum
275%
.032 – .100
0.2 sec., Min.; 10 sec. Max.
.125 – 6.3
0.6 sec., Min.; 10 sec. Max.
400%
.032 – .100
.04 sec., Min.; 3 sec. Max.
.125 – 6.3
.15 sec., Min.; 3 sec. Max.
1000%
.032 – .100
.01 sec., Min.; 0.3 sec. Max.
.125 – 6.3
0.02 sec., Min.; 0.3 sec. Max.
AGENCY APPROVALS:
Sheet III IEC 60127-2:* SEMKO, VDE
approved thru 6.3 amps. BSI approved 0.08-6.3 amps. Recognized under
the Components Program of Underwriters Laboratories and recognized
by CSA. 0213 series METI approved 1-5A.
VOLTAGE RATING:
250 VAC
INTERRUPTING RATINGS:
35 amperes or 10 x rated current;
whichever is greater.
ORDERING INFORMATION:
For axial leaded change 218 to 228 and 213 to 223.
218/228
213/223 Surge Withstand
Cartridge
Nominal
Nominal
Cartridge
Nominal
Nominal
Ampere
Catalog
Resistance
Melting I
2
t
Catalog
Resistance
Melting
Rating
Number
Cold Ohmns
A
2
Sec.
Number
Cold Ohms
I
2
t A
2
Sec.
.032
218.032
58.45
0.00305
–
–
–
.040
218.040
35.70
0.0055
–
–
–
.050
218.050
23.30
0.0071
–
–
–
.063
218.063
18.1
0.012
–
–
–
.080
218.080
12.6
0.0265
–
–
–
.100
218.100
8.95
0.0495
–
–
–
.125
218.125
4.41
0.150
–
–
–
.160
218.160
2.44
0.225
–
–
–
.200
218.200
1.60
0.350
0213.200
1.60
0.350
.250
218.250
1.05
0.555
0213.250
1.05
0.555
.315
218.315
0.848
1.14
0213.315
0.848
1.14
.400
218.400
0.535
1.35
0213.400
0.535
1.35
.500
218.500
0.370
2.90
0213.500
0.370
2.90
.630
218.630
0.275
4.80
0213.630
0.275
4.80
.800
218.800
0.073
1.99
0213.800
0.165
9.42
1
218 001
0.055
3.33
0213 001.
0.117
19.20
1.25
218 1.25
0.042
5.80
0213 1.25
0.081
27.15
1.6
218 01.6
0.032
10.61
0213 01.6
0.055
44.2
2
218 002
0.029
14.80
0213 002.
0.044
92.7
2.5
218 02.5
0.022
23.85
0213 02.5
0.030
138.0
3.15
218 3.15
0.017
39.20
0213 3.15
0.022
226.5
4
218 004
0.013
70.95
0213 004.
0.017
202
5
218 005
0.010
114.0
0213 005.
0.011
314
6.3
218 06.3
0.0075
204.0
0213 06.3
0.008
600
8
218 008
0.0059
350.5
–
–
–
10
218 010
0.0045
583.0
–
–
–
15
218 015
0.0030
1441.0
*
IEC Standards for 5 x 20 fuses do not include ratings above 6.3A, but are
under consideration.
5
(.197")
5.25
(.207")
40
(1.58")
.635
(.025")
20
(.787")
22.5 MAX
(.886)
Please contact Littelfuse for Average Time Current Curve
for 213/223 surge withstand.
1
228 and 223 Series are used for North American ordering.
®
®
V
D
E
213 000 XE
223 000
218 000 XE
228 000
213 000
218 000
Next
Previous