Littelfuse 472 Series User Manual
Axial lead & cartridge fuses, 472 series, pico, Ii time-lag fuse
![background image](/manuals/291800/1/background.png)
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13
Axial Lead & Cartridge Fuses
PICO
®
ll > Time-Lag > 472 Series
472 Series, PICO
®
II Time-Lag Fuse
Description
The 472 Series PICO
®
II, 125V rated time-Lag fuse is
designed for applications that require moderate in-rush
withstand and is in a space-saving subminature package.
Agency Approvals
Agency
Agency File Number
Ampere Range
E10480
500mA - 5A
Features
Electrical Characteristics
Applications
% of Ampere
Rating
Opening Time
100%
4 Hours, Min.
200%
120 Seconds, Max.
Ampere Rating
(A)
Amp Code
max
Voltage Rating
(V)
Interrupting
Rating
Nominal Cold
Resistance
(Ohms)
Nominal melting
I
2
t (A
2
sec)
Agency
Approvals
.500
.500
125
50 amperes at
125 VAC and VDC
0.174
0.1927
x
1.00
001.
125
0.078
0.9384
x
1.50
01.5
125
0.039
2.4081
x
2.00
002.
125
0.027
4.2363
x
2.50
02.5
125
0.0209
7.0838
x
3.00
003.
125
0.0187
9.3600
x
5.00
005.
125
0.0084
45.9000
x
Electrical Characteristics
• Moderate in–rush
withstand
• Small size
• Wide range of current
ratings available (500mA
to 5A)
• RoHS compliant
• Wide operating
temperature range
• Low temperature
de-rating
• Flat–panel display TV
• Lighting
• Game Console
• Power Supply
• Audio/Video Equipment
Additional Information