beautypg.com

Derale Performance 16" Tornado Electric Puller Fan, Premium Mounting Kit User Manual

Diagram #1, Diagram #2

background image

KIT CONTENTS

QTY. DESCRIPTION

1

Electric Fan Assembly

6

Mounting Rod

6

Mounting Clip

2

Mounting Feet

6

1x1 Foam Pad

1

Manual Switch

7ft

14 Gauge Wire

QTY. DESCRIPTION

1

30 Amp Fuse Holder

3

Blue Female Connector

1
2

#10 Blue Ring Terminal

3

Blue Butt Connector

4

#10 x 1/2” Sheet Metal Screws

4

4” Zip Ties

Blue Wire Tap Connector

Please read these instructions completely before beginning installation

TOOLS NEEDED

Standard Screw Driver
Drill
5/32” Drill Bit
12V Test Light
Wire Stripper
Crimping Tool
Dyke Pliers

PRE-INSTALLATION

Important:

This fan is factory setup for PULLER applications
Changing airflow direction

Note:

Tornado Electric Fans come from the factory with a product label

installed on one end of the fan shroud. Before installation check the product
label to confirm airflow direction and positive electric fan lead color.
Airflow direction will be shown with an arrow.

To change the airflow direction from the factory setting:
1.

Remove the Nut or Clip that holds the electric fan blade onto the motor
shaft.

2.

Carefully remove the fan blade from the motor shaft.

This is an interference fit and requires some effort.

3.

Flip the fan blade upside down and reinstall onto the motor shaft. Make
sure the roll pin on the motor shaft is aligned with the slot on the fan blade.

4.

Reinstall nut or clip on motor shaft.

Important: For Puller applications use the referenced wire colors stated on the
Product Label. For Pusher applications the two wires MUST be reversed to
change airflow direction.

Diagram #1

Puller Fan

Pusher Fan

Air Flow

Engine

Radiator

16516-InstructionSheet.cdr

INSTALLATION INSTRUCTIONS

TORNADO ELECTRIC FAN KIT

PART # 16516

IMPORTANT

This fan assembly is designed for
both PUSHER and PULLER
applications.
To change airflow direction from
the factory setting, you MUST
follow the directions below or
performance will be compromised.
(See Diagram #1)

(Continues on Page 2)

Derale Performance, Los Angeles, CA

800.421.6288 www.derale.com

ELECTRIC FAN MOUNTING

Note: This Electric Fan Assembly requires 6 mounting positions. Four Mounting Rods will be installed in the locations molded in

the shroud, the additional two Mounting Rods will be used with the 2 supplied Mounting Feet. (See Diagram #2)

1.

Identify the 2 Mounting Feet supplied and install onto the Electric Fan Assembly by sliding them into the slots on the Electric

Fan Assembly. See Diagram #2 for recommended locations.

2.

Position the electric fan against the radiator in

the desired location.

3.

Take the Plastic Rods provided and install

through the four mounting holes on the shroud
pushing them slowly into and through the
radiator core. (See Diagram #2)

Do not use excessive force when

pushing Plastic Rods through radiator core.
Excessive force could cause damage to the
radiator fins and/or core. Plastic Rods should
not be inserted thru both the radiator and the
condenser cores.

4.

Take the 1 x 1 Foam pads provided and install

them onto the Plastic Rods now protruding
through the radiator core.
(See Diagram #3)

5.

Take the Plastic Clips provided, making sure

they are in the correct direction (Derale writing
out) install onto the Plastic Rods and cinch them
until the 1 x 1 Foam Pads are compressed.
(See Diagram #3)

6.

Cut off the excess Plastic Rod.

Caution:

Diagram #2

Mounting Clips

1 x 1

Foam

Pads

Mounting

Feet

Mounting

Rods