Position adapter bracket (

A) at desired position on wall

.

Use mounting bracket, making sure that it is level, as a

template to mark holes. Drill six 1/4" (6 mm) dia. holes

to a minimum depth of 2-1/2" (64 mm). Concrete must

be 2000 psi density minimum. Insert anchors (

J) in holes

flush with wall as shown in figure 5.3. Place wall mount

assembly over anchors and secure with #14 x 2-1/2"

(6 mm x 65 mm) wood screws (

E) and washers (I) as

shown in figure 3.4. Make sure wall plate is level and

tighten all fasteners.

Installation to Solid Concrete and Cinder Block Wall

3

• Tighten wood screws firmly, but do not overtighten.

Overtightening can damage the screws, greatly re-

ducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid

part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-

tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to

avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

WARNING

I

A

fig 3.4

• Concrete anchors are

not intended for attachment to

concrete wall covered with a layer of plaster, drywall,

or other finishing material as shown below. If mount-

ing to concrete wall covered with plaster/drywall is

unavoidable, plaster/drywall (up to 5/8" thick) must

be counter bored as shown below. Be sure concrete

anchors do not pull away from concrete when tight-

ening screws. If plaster/drywall is thicker than

5/8", custom fasteners must be supplied by installer.

WARNING

CINDER BLOCK

SOLID CONCRETE

E

J

1

3

2

J

Drill holes and insert anchors (

J).

Place plate (

A) over anchors (J) and secure with screws (E) with

washers (

I).

Tighten all fasteners.