B&B Electronics 232BRC - Manual User Manual
Page 19
232BRC-0812 Manual
17
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445
Step 4: Connect the 232BRC to be copied to the serial (COM)
port of the PC. Install the setup jumper. Apply power to the
232BRC.
Step 5: Click Next.
Step 6: Select Save As from the File menu. Save the
configuration to disk.
Step 7: Disconnect the first 232BRC from the COM port.
Step 8: Connect the destination 232BRC to the serial (COM) port
of the PC. Install the setup jumper. Apply power to the
232BRC.
Step 9: Select File/Load File and load the saved configuration.
Step 10: Click Configure 232BRC
Once the configuration file has been loaded, any number of 232BRC
modules can be set to the same parameters by connecting and
configuring each in turn.
Final System Installation
After successfully completing and testing the 232BRC
configuration, remove the setup jumper. Place the unit back in the
enclosure and re-insert the 4 Phillips screws.
NOTE: The 232BRC will not function properly until the setup
jumper is removed.
Default Parameters
When shipped, the 232BRC comes set up for the following
parameters for ports A and B:
Data Rate = 9600 bps
Data Bits = 8
Stop Bits = 1
Parity = None
Handshaking = None