8

Baud rates that are not evenly divisible into 1.152 MHz can also

be used, but the actual baud rate will vary slightly from the requested
rate. This may or may not cause data errors, depending on the
attached equipment. Most standard UARTs can accept a 5% to 10%
difference in baud rate before errors occur.


For example:

Desired Baud Rate = 20 kbps

1.152 MHz / 20 kbps = 57.6

Actual Rate = 1.152 MHz / 58 = 19.862 kbps

%error = (20 kbps

– 19.862 kbps) / 20 kbps * 100

%error = 0.7%


Data bits:

Each port can be configured for Five, Six, Seven or Eight data

bits.

NOTE:

If the ports are set up differently, the port set for fewer

data bits cannot transmit the upper most significant bits.


Parity:

Each port can be configured for Even, Odd, or No parity. The

parity should be selected to match the connected device.


Stop Bits:

Each port can be configured for one or two stop bits. The stop

bits should be selected to match the connected device.

Flow Control:

Hardware(RTS/CTS) Handshaking:


Each port can be independently configured to hold data until

its input handshake line goes high. On Port A, pin seven (RTS)
would have to be held high by the connected device in order for the
232BRC to send data. On Port B, pin eight (CTS) needs to be held
high by the connected device for the 232BRC to send data.

Connected devices can prevent data from being sent from the

232BRC by holding their corresponding handshake lines low. This
corresponds to pin seven on Port A and pin eight on Port B. See
Appendix A for a complete table of signal directions.