beautypg.com

B&B Electronics 850-14300--39 - Manual User Manual

Page 12

background image

8

This feature can be controlled by SNMP management software
(iView

2

) when the iMcV-DS3/E3/STS module is installed in a

managed chassis.

** WARNING **

Enabling FiberAlert on both of the iMcV-DS3/E3/STS modules
will cause them both to stop transmitting unrecoverably when a
fault occurs. This feature is designed to only be enabled on
the Remote iMcV-DS3/E3/STS module.

Transmit LIU Waveshape (Line Build-Out)

This switch selects the optimal transmit waveshape for the
line build-out distance on the coax line. The transmit
waveshape can be set for a distance of either 0 to 255 feet
or over 255 feet. This feature corrects problems related
to cabling (i.e. cross-talk, electromagnetic interference,
etc.). Improperly setting this switch will cause signal
degradation.

By default this feature is set to > 255 FEET.

This feature can be controlled by SNMP management software
(iView

2

) when the iMcV-DS3/E3/STS module is installed in a

managed chassis.

Transmit Data Source

These switches select the transmit mode used by the iMcV-
DS3/E3/STS module. The transmit modes that can be selected
include the following:

Standard data

Unframed All Ones (diagnostic)

Alternating Ones and Zeros (diagnostic)

Pseudorandom bit sequence (diagnostic)

These standard Telco transmission pattern modes are
provided to help diagnose transmission errors in the line.

By default this feature is set to STANDARD DATA.

This feature can be controlled by SNMP management software
(iView

2

) when the iMcV-DS3/E3/STS module is installed in a

managed chassis.