beautypg.com

B&B Electronics FOSTCDRI-ST - Quick Start Guide User Manual

Fostcdri-sx quick start guide, Front panel, Wiring terminal information

background image

p/n 8405 FOSTCDRI-Sx-1112qsg-1/4

© 2009 by B&B Electronics. All rights reserved.

www.bb-elec.com [email protected] [email protected]

International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104

European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445

PR

O

D

U

C

T

INF

ORM

A

TIO

N

B

&

B

ELE

C

T

R

ON

ICS






































































FOSTCDRI-Sx

Quick Start Guide

Package Contents

FOSTCDRI-Sx Industrial Serial To Single-mode Fiber

Optic Converter

Datasheet (One per shipment)
Power Terminal Block (installed)
Serial Terminal Block (installed)
Fiber Optic Dust Cover (installed)

If any item is missing or damaged, contact B&B Electronics
for a replacement

Front Panel

1

Power TB

2 Position, Removable

2

PWR LED

ON When Power Applied

3

Fiber Port

Single-mode, SC or ST Connectors

4

Fiber RX LED

Flashes when data received

4

Fiber TX LED

Flashes when data transmitted

5

Serial Port TB

5 Position, Removable

6

Serial Switch

Selects RS-232 or RS-422/485 Mode

7

DIP Switch

12 Position

Wiring Terminal

Information

1. Copper Wire Only
2. One Conductor Per Terminal
3. Wire Range 28 to 16 AWG
4. Tightening Torque, 1.7 lb-in.
5. Temperature Rating of Field Wiring - 105°C (221° F)

minimum sized for 60° C (140°F) ampacity.

Note: The label
for the serial
connection
terminal block is
not visible with
the TB installed.
This detail is
provided for
reference.

DIP Switch (SW1)

Pos

ON

OFF

1

RS-485

RS-422

2

HALF-DUPLEX

FULL-DUPLEX

3

2-WIRE

4-WIRE

4

2-WIRE

4-WIRE

5

TERMINATION IN

TERMINATION OUT

6

TX BIAS OUT

TX BIAS IN

7

RX BIAS OUT

RX BIAS IN

8

57.6 KBPS

9

38.4 KBPS

10

19.2 KBPS

11

9.6 KBPS

12

MULTI-DROP

POINT-TO-POINT

Terminal Block

Terminal

RS-232

T-

Output

T+

Not Used

R-

Input

R+

Not Used

G

Ground

Terminal

RS 4852-Wire

RS-422/4854-Wire

T-

Data A(-)

TD A(-)

T+

Data B(+)

TD B(+)

R-

Not Used

RD A(-)

R+

Not Used

RD B(+)

G

Ground

Ground

RS-422/485 Baud Rate /

Timeout

SW1

SW1

SW1

SW1

Timeout

Baud

8

9

10

11

(ms)

9600

OFF

OFF

OFF

ON

1.30

19.2K

OFF

OFF

ON

OFF

0.56

38.4K

OFF

ON

OFF

OFF

0.27

57.6K

ON

OFF

OFF

OFF

0.22

76.8K

ON

OFF

ON

ON

0.14

115.2K

ON

OFF

ON

OFF

0.10