B&B Electronics 850-18510 - Manual User Manual
Page 6

3
for that slot; the settings of a new module are adopted and stored in the
IE-iMcV-Gigabit TX/SFP
The SNMP Write Lock switch does not impact any iMcV-Module or IE-iMcV-
Module with Configuration Control. Removing and installing a new SNMP
Management Module will no longer impact these modules either. However, if
there is a mixture of iMcV-Modules with and without Configuration Control, the
Write Lock Switch and a new SNMP Management Module must be taken into
consideration.
If the command cleandb is applied to an SNMP Management Module, all the
settings for the modules will be removed, but the Configuration Control modules
will still be based on the last change made, while those without Configuration
Control will be set to their default settings.
NOTE
If the end user has a mixture of standard iMcV-Modules as well as Configuration
Control iMcV-Modules, it is important to understand how SNMP and DIP Switches will
impact the cards depending on their capability. Standard iMcV-Modules cannot be
upgraded to Configuration Control capability, so it is strongly recommended to set the
DIP Switches on the modules and then configure them via software to match the same
settings.
Unmanaged Modules
Before installing, configure the IE-iMcV-Gigabit TX/SFP Module for desired
features. The diagram indicates the available features and settings for the
module. After configuring the switch for the desired settings, install the module
and connect the appropriate cables. For further information, refer to the
Installing an iMcV-Module section.