beautypg.com

Timing characteristics (see figure 6) – Rainbow Electronics MAX111 User Manual

Page 6

background image

MAX110/MAX111

Low-Cost, 2-Channel, ±14-Bit Serial ADCs

6

_______________________________________________________________________________________

Note 10:

Timing specifications are guaranteed by design. All input control signals are specified with t

r

= t

f

= 5ns

(10% to 90% of +5V) and timed from a +1.6V voltage level.

Note 1:

These specifications apply after auto-null and gain calibration. Performance at power-supply tolerance limits is guaranteed
by power-supply rejection tests. Tests are performed at V

DD

= 5V and V

SS

= -5V (MAX110).

Note 2:

32,768 LSBs cover an input voltage range of ±V

REF

(15 bits). An additional bit (OFL) is set for V

IN

> V

REF

.

Note 3:

Guaranteed by design. Not subject to production testing.

Note 4:

DNL is less than ±2 counts (LSBs) out of 2

15

counts (±14 bits). The major source of DNL is noise, and this can be further

improved by averaging.

Note 5:

See

3-Step Calibration

section in text.

Note 6:

V

REF

= (V

REF+

- V

REF-

), V

IN

= (V

IN1+

- V

IN1-

) or (V

IN2+

- V

IN2-

). The voltage is interpreted as negative when the voltage at

the negative input terminal exceeds the voltage at the positive input terminal.

Note 7:

Conversion time is set by control bits CONV1–CONV4.

Note 8:

Tested at clock frequency of 1MHz with the divide-by-2 mode (i.e. oversampling clock of 500kHz). See

Typical Operating

Characteristics

section for the effect of other clock frequencies. Also read the

Clock Frequency

section.

Note 9:

This current depends strongly on C

XCLK

(see

Applications Information

section).

TIMING CHARACTERISTICS (see Figure 6)

(V

DD

= 5V, V

SS

= -5V (MAX110), T

A

= T

MIN

to T

MAX

, unless otherwise noted. Typical values are at T

A

= +25°C.)

MHz

1.1

3.0

MAX11_ BM

RC Oscillator Frequency

1.3

2.8

MAX11_ _C/E

2.0

T

A

= +25°C

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

80

60

CS to SCLK Hold Time
(Note 10)

t

CSH

0

ns

DIN to SCLK Setup Time
(Note 10)

t

DS

100

ns

DIN to SCLK Hold Time
(Note 10)

t

DH

0

ns

100

60

80

CS to SCLK Setup Time
(Note 10)

t

CSS

100

ns

120

SCLK, XCLK Pulse Width
(Note 10)

t

CK

160

ns

0

35

80

0

100

Data Access Time
(Note 10)

t

DA

0

120

ns

0

60

100

0

120

SCLK to DOUT Valid
Delay (Note 10)

t

DO

0

140

ns

35

80

Bus Relinquish Time
(Note 10)

t

DH

120

ns

MAX11_ BM

MAX11_ _C/E

T

A

= +25°C

MAX11_ BM

MAX11_ _C/E

CONDITIONS

MAX11_ _C/E

MAX11_ _C/E

MAX11_ BM

T

A

= +25°C

MAX11_ BM

T

A

= +25°C

C

LOAD

= 50pF

T

A

= +25°C

C

LOAD

= 50pF

MAX11_ _C/E

T

A

= +25°C

MAX11_ BM

T

A

= +25°C

MAX11_ _C/E/M